Teledyne API T802 Paramagnetic O2 Analyzer Operation Manual Introduction, Features and Options

19

Option Option

Number Description/Notes Reference

Carrying Strap/Handle Side-mounted strap for hand-carrying analyzer
29
Extends from “flat” position to accommodate hand for carrying.
Recesses to 9mm (3/8”) dimension for storage.
Can be used with rack mount brackets, Option 21.
Cannot be used with rack mount slides.
N/A
CAUTION - GENERAL SAFETY HAZARD

THE T802 WEIGHS ABOUT 28 POUNDS (12.7 KG). TAKE CARE TO

AVOID PERSONAL INJURY WHEN LIFTING/CARRYING THE

ANALYZER.

ALSO, DISCONNECT ALL CABLES AND TUBING FROM THE

ANALYZER BEFORE MOVING IT.

Analog Inputs w/USB port Used for connecting external voltage signals from other instrumentation (such as
meteorological instruments).
64B
Also can be used for logging these signals in the analyzer’s internal
DAS. (See Option 64A for USB port only).
Sections 3.3.1.2
and 5.9.8
Current Loop Analog
Outputs
Adds isolated voltage-to-current conversion circuitry to the analyzer’s analog
outputs.
41
Can be configured for 0-20 mA or 4-20 mA.
May be ordered separately for any of the analog outputs.
Can be installed at the factory or retrofitted in the field.
Section 3.3.1.4
Parts Kits Spare parts and expendables
42A Expendables Kit for analyzer with a pump, includes a recommended
set of expendables for one year of operation. Appendix B
42D Expendables Kit for analyzer without a pump, includes a
recommended set of expendables for one year of operation. Appendix B
Communication Cables For remote serial, network and Internet communication with the analyzer.
Type Description
60A RS-232
Shielded, straight-through DB-9F to DB-25M cable, about
1.8 m long. Used to interface with older computers or
code activated switches with DB-25 serial connectors.
60B RS-232
Shielded, straight-through DB-9F to DB-9F cable of about
1.8 m length.
60C Ethernet
Patch cable, 2 meters long, used for Internet and LAN
communications.
60D USB
Cable for direct connection between instrument (rear
panel USB port) and personal computer.
Sections 3.3.1.8
and 6
Concentration Alarm Relay Issues warning when gas concentration exceeds limits set by user.
61
Four (4) “dry contact” relays on the rear panel of the instrument. This
relay option is different from and in addition to the “Contact Closures”
that come standard on all TAPI instruments.
Section 3.3.1.7
RS-232 Multidrop Enables communications between host computer and up to eight analyzers.
62
Multidrop card seated on the analyzer’s CPU card.
Each instrument in the multidrop network requires this card and a
communications cable (Option 60B).
Section 3.3.1.8