CC2420

SYNCWORD (0x14) - Sync Word

 

 

 

 

 

 

 

 

 

Bit

Field Name

 

Reset

R/W

Description

15:0

SYNCWORD[15:0]

 

0xA70F

R/W

Synchronisation word. The SYNCWORD is processed from the

 

 

 

 

 

least significant nibble (F at reset) to the most significant nibble

 

 

 

 

 

(A at reset).

 

 

 

 

 

SYNCWORD is used both during modulation (where 0xF’s are

 

 

 

 

 

replaced with 0x0’s) and during demodulation (where 0xF’s are

 

 

 

 

 

not required for frame synchronisation). In reception an implicit

 

 

 

 

 

zero is required before the first symbol required by SYNCWORD.

 

 

 

 

 

The reset value is compliant with IEEE 802.15.4.

 

 

 

 

 

 

TXCTRL (0x15) - Transmit Control Register

 

Bit

Field Name

Reset

R/W

 

 

15:14

TXMIXBUF_CUR[1:0]

2

R/W

 

13

TX_TURNAROUND

1

R/W

 

 

 

 

12:11

TXMIX_CAP_ARRAY[1:0]

0

R/W

10:9

TXMIX_CURRENT[1:0]

0

R/W

8:6

PA_CURRENT[2:0]

3

R/W

5

-

1

W1

4:0

PA_LEVEL[4:0]

31

R/W

Description

TX mixer buffer bias current.

0:690uA

1:980uA

2:1.16mA (nominal)

3:1.44mA

Sets the wait time after STXON before transmission is started.

0 : 8 symbol periods (128 us)

1 : 12 symbol periods (192 us)

Selects varactor array settings in the transmit mixers.

Transmit mixers current:

0:1.72 mA

1:1.88 mA

2:2.05 mA

3:2.21 mA

Current programming of the PA

0:-3 current adjustment

1:-2 current adjustment

2:-1 current adjustment

3:Nominal setting

4:+1 current adjustment

5:+2 current adjustment

6:+3 current adjustment

7:+4 current adjustment

Reserved, write as 1.

Output PA level. (~0 dBm)

SWRS041B

Page 66 of 89

Page 66
Image 66
Texas Instruments 3138 155 232931 manual Syncword 0x14 Sync Word, Txctrl 0x15 Transmit Control Register