D. Return Air Filter

All installations and services must be performed by qualified service personnel.

D. Return Air Filter

The Return Air Filter(s): Provided with this unit is a permanent type filter. This filter(s) should be inspected and when dirty, cleaned or replaced, if necessary to assure proper furnace operation. Follow the cleaning, removal and replacement procedure below.

Filter Maintenance Procedure:

The filter rack will be located between the return air plenum and the return air opening of the furnace. See Figure 11 for MHA1/MDA1 series units. Slide dirty filter out of the filter rack. Clean the filter by vacuuming, rinsing with tap water, hosing or dipping in an ordinary detergent solution. After cleaning, replace the completely dry filter in the rack. If the filter has a mesh, the mesh side of the filter must be towards the furnace.

FILTERS

RETURN AIR

SUPPLY AIR

 

RETURN

 

AIR

FRONT DOOR

BLOWER

 

ACCESS

 

DOOR

COMBUSTIBLE

FLOOR BASE

TYPICAL FILTER

LOCATION

MHA1 SERIES

SUPPLY AIR

MDA1 SERIES

Figure 11: Filter Location

FILTER REPLACEMENT

Should the filter used require replacement, see Table 2 in Section II, I, of this manual for minimum filter areas required for the different types of filters available to ensure an adequate replacement is selected.