All installations and services must be performed by qualified service personnel.

APPENDIX G: MID-EFFICENCY FURNACE SPECIFICATIONS

MID-EFFICIENCY HIGHBOY GAS FURNACE SPECIFICATIONS5

Model NO.

MHA1-50

 

MHA1-75

 

MHA1-100

MHA1-125

Heat input rate (BTUH)

50,000

 

75,000

 

100,000

 

125,000

Heating capacity (BTUH)1

40,000

 

59,000

 

79,000

 

99,000

Nominal temp. rise

 

 

 

 

 

 

 

 

70°F

 

 

 

 

 

 

Heating fan speed

 

LOW

 

LOW

 

 

LOW

 

 

LOW

Burner orifice size for nat. gas

 

 

 

 

 

 

 

 

0.0935”

(#42)

 

 

 

 

 

 

 

 

Burner orifice size for L.P. gas

 

 

 

 

 

 

 

0.0591” (1.5 mm)

 

 

 

 

 

 

AFUE %

 

80.0

 

80.0

 

 

80.0

 

 

 

80.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Height of casing

 

 

 

 

 

 

 

 

44-1/4”

 

 

 

 

 

 

Width of casing

 

17”

 

17”

 

 

21”

 

 

 

24”

Depth of casing

 

 

 

 

 

 

 

 

27

½”

 

 

 

 

 

 

Warm air outlet2

15” x 18”

 

15” x 18”

 

19” x 18”

22” x 18”

Return air inlet2

25” x 16”

 

25” x 16”

 

25” x 16”

25” x 16”

Approx. shipping weight

131 LBS

 

143 LBS

 

170 LBS

186 LBS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dia. of flue (vertical vent)

 

3”

 

4”

 

 

4”

 

 

 

4”

Dia. of flue (sidewall vent)3

 

3”

 

4”

 

 

4”

 

 

 

4”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM @ .2” & .5” W.C. external

.2”

 

 

.5”

 

.2”

.5”

 

.2”

.5”

.2’

 

 

.5”

static pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

@HI speed

950

 

 

830

 

1495

 

 

1335

 

1795

 

 

1560

 

2245

 

 

1970

@MH speed

860

 

 

740

 

1205

 

 

1125

 

1590

 

 

1410

 

1885

 

 

1710

@ML speed

-

 

 

-

 

920

 

 

865

 

1410

 

 

1290

 

1605

 

 

1510

@LO speed

580

440

 

750

 

 

700

 

1240

 

 

1160

 

1350

 

 

1300

 

 

 

 

 

 

 

 

 

 

Blower motor type & frame

 

 

 

 

Permanent split capacitor, air over, 48 Y

 

 

 

 

Blower motor nominal HP

 

1/5

 

1/3

 

 

1/2

 

 

 

3/4

Blower motor full load amps

 

3.25

 

6.0

 

 

8.0

 

 

 

11.0

Motor shaft diameter

 

 

 

 

 

 

 

 

½”

 

 

 

 

 

 

 

 

 

Direction of rotation (shaft end)

 

 

 

 

 

 

 

 

Clockwise

 

 

 

 

 

 

No. of speeds

 

3

 

4

 

 

4

 

 

 

4

Run capacitor

10 mfd

 

10 mfd

 

10 mfd

15 mfd

 

370 VAC

 

370 VAC

 

370 VAC

440 VAC

Blower size

10-7 R DD

 

10-9 R DD

 

10-9 R DD

10-9 R DD

Size of filters

(1) – 1” x 24 ¾” x

 

(1) – 1” x 24 ¾” x

 

(1) – 1” x 24 ¾” x

(1) – 1” x 24 ¾”

 

 

15 ¾”

 

15 ¾”

 

15 ¾”

x 19 ¾”

Largest recommended air

 

2 Ton

 

3.5 Ton

 

4 Ton

5 Ton

conditioner4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical power requirements

 

 

 

 

 

115 volts, 60 Hz., 1 phase

 

 

 

 

Min. Fuse size

15 AMP

 

15 AMP

 

15 AMP

20 AMP

 

 

 

 

ACCESSORY ITEMS

 

 

 

 

 

 

 

 

 

 

 

Filter Rack

AOPS 7547

 

AOPS 7547

 

AOPS 7547

AOPS 7375

Flange dimensions2

24-1/2” X 15”

 

24-1/2” X 15”

 

24-1/2” X 15”

24” X 19”

NOTES:

1.BTU output based on annual fuel utilization efficiency rated by manufacturer.

2.On all outlet and inlet dimensions, the first dimension is width.

3.The MHA1/MDA1 furnaces are approved for sidewall venting using only an approved sidewall power venter. Refer to Side Wall Venting section of the Installation and service manual provided with the furnace for additional information.

4.To permit largest recommended air conditioning (at .5 static pressure), selection of the highest motor speed is required.

5.All specifications are subject to change without notice.

56

Page 59
Image 59
Thermo Products MHA1-50N, MDA1-50N, MHA1-75N, MHA1-100N, MHA1-125N, MDA1-75N Appendix G MID-EFFICENCY Furnace Specifications