Limitorque MX DeviceNet Field Unit FCD
Table 4.32 – Continued |
|
|
|
|
|
|
|
|
|
| ||
Attribute ID |
| Access Rule |
| Name |
| Data Type |
| Description |
| Semantics of Value | ||
20 |
| RO |
| TQ_Status_4 |
| UINT |
| MB_TQ_Open_ |
| Engineering Use | ||
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
| Breakout_Last |
|
|
|
|
21 |
| RO |
| TQ_Status_5 |
| UINT |
| MB_TQ_Close_ |
| Engineering Use | ||
|
|
|
|
|
|
|
| Breakout_Last |
|
|
|
|
22 |
| RO |
| TQ_Status_6 |
| UINT |
| MB_TQ_Open_ |
| Engineering Use | ||
|
|
|
|
|
|
|
| Ending_Last |
|
|
|
|
23 |
| RO |
| TQ_Status_7 |
| UINT |
| MB_TQ_Close_ |
| Engineering Use | ||
|
|
|
|
|
|
|
| Ending_Last |
|
|
|
|
24 |
| RO |
| TQ_Status_8 |
| UINT |
| MB_TQ_Close_ |
| Engineering Use | ||
|
|
|
|
|
|
|
| Peak_Last |
|
|
|
|
25 |
| RO |
| TQ_Status_9 |
| UINT |
| MB_TQ_Open_ |
| Engineering Use | ||
|
|
|
|
|
|
|
| Peak_Last |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
26 |
| RO |
| TQ_Status_10 |
| UINT |
| MB_TQ_Open_ |
| Engineering Use | ||
|
|
|
|
|
|
|
| Breakout_Ref |
|
|
|
|
27 |
| RO |
| TQ_Status_11 |
| UINT |
| MB_TQ_Close_ |
| Engineering Use | ||
|
|
|
|
|
|
|
| Breakout_Ref |
|
|
|
|
28 |
| RO |
| TQ_Status_12 |
| UINT |
| MB_TQ_Open_ |
| Engineering Use | ||
|
|
|
|
|
|
|
| Ending_Ref |
|
|
|
|
29 |
| RO |
| TQ_Status_13 |
| UINT |
| MB_TQ_Close_ |
| Engineering Use | ||
|
|
|
|
|
|
|
| Ending_Ref |
|
|
|
|
30 |
| RO |
| TQ_Status_14 |
| UINT |
| MB_TQ_Close_ |
| Engineering Use | ||
|
|
|
|
|
|
|
| Peak_Ref |
|
|
|
|
31 |
| RW |
| Travel_Limit_Low |
| UINT |
| Lower limit of the |
| Range 0 – 1000 | ||
|
|
|
|
|
|
|
| valve position in |
| Default = 0 | ||
|
|
|
|
|
|
|
| percent of travel |
|
|
|
|
|
|
|
|
|
|
|
| span |
|
|
|
|
32 |
| RW |
| Travel_Limit_Up |
| UINT |
| Upper limit of the |
| Range 0 – 1000 | ||
|
|
|
|
|
|
|
| valve position in |
| Default = 0 | ||
|
|
|
|
|
|
|
| percent of travel |
|
|
|
|
|
|
|
|
|
|
|
| span |
|
|
|
|
33 |
| RW |
| Valve_Maint_ Date |
| SHORT- |
| Date of last valve |
| String length is limited | ||
|
|
|
|
|
| STRING |
| maintenance |
| to 16 char. Default = 0 | ||
|
|
|
|
|
|
|
|
|
| (empty) |
| |
34 |
| RW |
| Valve_Serial_Num |
| SHORT- |
| Serial number of |
| String length is limited | ||
|
|
|
|
|
| STRING |
| the valve belonging |
| to 16 char. Default = 0 | ||
|
|
|
|
|
|
|
| to the positioner of |
| (empty) | ||
|
|
|
|
|
|
|
| electronic device |
|
|
|
|
35 |
| RO |
| Valve_status_0 |
| WORD |
| Requested relay |
| Default = 0 | ||
|
|
|
|
|
|
|
| channel value |
|
|
|
|
36 |
| RO |
| Valve_status_1 |
| WORD |
| Status Register |
| Default = 0 | ||
|
|
|
|
|
|
|
| – Modbus Register |
|
|
|
|
|
|
|
|
|
|
|
| 9 |
|
|
|
|
37 |
| RO |
| Valve_status_2 |
| WORD |
| Fault Register |
| Default = 0 | ||
|
|
|
|
|
|
|
| – Modbus Register |
|
|
|
|
|
|
|
|
|
|
|
| 10 |
|
|
|
|
38 |
| RO |
| Valve_status_3 |
| WORD |
| Digital Output |
| Default = 0 | ||
|
|
|
|
|
|
|
| Register – Modbus |
|
|
|
|
|
|
|
|
|
|
|
| Register 11 |
|
|
|
|
39 |
| RO |
| Valve_status_4 |
| WORD |
| Digital Input #1 |
| Default = 0 | ||
|
|
|
|
|
|
|
| Register – Modbus |
|
|
|
|
|
|
|
|
|
|
|
| Register 12 |
|
|
|
|
40 |
| RW |
| Valve_status_5 |
| WORD |
| Digital Input #2 |
| Default = 0 | ||
|
|
|
|
|
|
|
| Register – Modbus |
|
|
|
|
|
|
|
|
|
|
|
| Register 13 |
|
|
|
|
Continued on next page |
|
|
|
|
|
| 27 | |||||
|
|
|
|
|
|
|
|
|