7.2. Optional Modules7.2.1. D-001T (2-Channel Input Module)
The D-001T module is designed for use with the 9000 Series amplifiers. Up to 4 modules (8 channels in total) can be inserted into the amplifier.
The module can handle signals ranging from microphone level (–60 dB) to line level (–10 dB) in 9 input sensitivity levels.
Phantom power (24 V) can be supplied for microphone level (–60 dB to –30 dB) signals. The D-001T module has an internal digital signal processor that can process input signals.
The D-001T module is required to use a VOX (Voice Operated Exchange) function and input channel level meter.
1.Monaural input terminals [1, 2]
Electronically-balanced 3P removable terminal blocks. Input level: –60 dB to –10 dB selectable.
Input impedance is 10 kΩ when the phantom power is OFF, and 3 kΩ when ON.
1
2
Hot
Cold
Earth
7.2.2. T-001T (Audio Output Expansion Module)
The T-001T module is designed for use with the 9000 Series amplifiers and can expand 2 output channels per module.
Since the main unit has 2 fixed outputs, the audio output can be expanded to 8 channels by using a maximum of 3 modules (6 channels).
T-001T | 2. Monaural output terminals [1, 2] |
| Electronically-balanced 3P removable terminal blocks. |
1 | Output level: | 0 dB |
Hot | Output impedance: 600 Ω |
Cold | For unbalanced connection, connect the unit's Hot and Earth |
Earth | terminals to the connected equipment's Signal and GND |
2 | terminals, respectively. (Keep the unit's Cold terminal free.) |
2
Hot
Cold
Earth