(C18) Interlock output control display (Only in the normal matrix operation)

C - O U T 0 1 E V E N T N O N E

When the displayed control output (C-OUT01 in this example) is designated as interlock output in the Event setting, its Event number is displayed.

If not designated as interlock output, the NONE indication is displayed in place of the Event number.

(C19) Control output function selection

C - O U T 0 1 N O N E

Sets the functions to be assigned to the control output terminals.

Setting Range NONE (default), POWER

(C20) (When the control output function is set to POWER:)

C - O U T 0 1 P O W E R

Turning on the power switch closes the control output terminal.

Assigning the function to this terminal overwrites the previously set function on it if there is.

[When the function is set to POWEROFF:]

(C21) Memory erasure or storage setting

P O W E R O F F – D E L

Set whether or not to save data of the volume level set in normal operation status when the AC power supply is cut off.

Setting Range DEL (default), SAVE

DEL: Data not saved.

SAVE: Saves data at the time when the Memory key is pressed.

This setting is for the case when the AC power supply is cut off.

When turned off using the unit's front-mounted power switch, the unit automatically saves the data of all the set volume levels.

[When the function is set to VOX TIME]

(C22) VOX release time setting

V O X R E L E A S E T I M E 5

Sets the time (seconds) required for the muted signal to return to the original level after the VOX activating input signal decreases below the threshold level.

Setting Range 1 – 8 (default: 5)

59