16.1.4. Operation by control input

[Pulse trigger]

Use this method to activate operations for which no definite end can be defined, such as Volume Up/Down, BGM and Base pattern activation, and BGM End. Minimum pulse width is 100 ms.

Over 100 ms

High

Low

State changes at the falling edge, and is maintained until changed by another trigger.

BASE

BGM END

Broadcast state

BGM broadcast in progress

[Event activation by pulse trigger, and a busy signal provided]

When the external equipment that provides a busy signal during its operation is used for priority broadcasts, the state of broadcast and busy signal after Event is pulse-triggered is as follows.

Event activation

Busy signal

Broadcast state

Priority broadcast in progress

93