14. RESTORING FACTORY DEFAULT SETTING

Follow the procedures below to return all settings to default values while using the unit in the matrix mode. Details of the default values are shown on the next page, "Default Setting Table."

Step 1. Hold down the Utility menu key for 2 seconds or more when in normal use state.

Normal operation mode

Step 2. Using the Parameter setting knob, select UTILITY SETTING, then press the Right shift key.

1

UTILITY

Step 3. Using the Parameter setting knob or UP/Down shift key, select MEMORY, then press the Right shift key.

Step 4. Press the Enter key when the "INITIALIZE OK?" indication is displayed.

To cancel initialization, press the Left shift key or Escape/Back key to revert back to the previous screen.

Setting menu screen

I N P U T – S E T T I N G

PARAMETER

2

U T I L I T Y – S E T T I N G

U T I L I T Y

C - I N

PARAMETER

3 or

U T I L I T Y M E M O R Y

I N I T I A L I Z E O K ?

ENTER

4