(C13) (When the control input function is set to EMG-MUTE:)

C - I N 0 1 – E M G - M U T E

Assign the function that simultaneously mutes all output channels to the control input. Closing the control input terminal mutes all output channels.

This function is used to mute the output provided from the unit during emergency broadcast operation. Assigning a function to this terminal overwrites the previously set function on it if there is.

(C14) Interlock output control setting (EMG-MUTE)

C - I N 0 1 – S Y N C O F F

Perform ON/OFF setting for the function that closes the control output terminal in synchronization with the control input terminal closure of the set number.

Setting Range ON, OFF (default)

(C15) Interlock output terminal setting (EMG-MUTE)

C - I N 0 1 – C O U T 0 1

This screen is displayed only when the interlock output control setting is set to ON.

Set the control output terminal which is closed in synchronization with the control input of the set number. Assigning a function to this terminal overwrites the previously set function on it if there is.

Setting Range COUT01 – 04, C-OUT01 – 12 when C-001T is used (default: COUT01) Note: When the interlock output control ON/OFF setting is ON.

(C16) (When the control input function is set to BGMEND) (Only in the 1-channel or 2-channel output operation)

C - I N 0 1 – B G M E N D

Assign the BGM end function to the control input terminal.

Closing the control input terminal turns off all Events with Priority 8 or all input channels with Priority 8. Assigning a function to the control input terminal or ZM-9001/9002's control button overwrites the previously set function on it if there is.

[When the function is set to C-OUT:]

(C17) Control output number selection

C - O U T 0 1 N O N E

Setting Range 01 – 04, 01 – 12 when C-001T is used (default: 01)

In the normal matrix operation, when the Down shift key is pressed with the control output function set to NONE and the cursor at the control input number, the Event number assigned to that control output number can be confirmed.

If no Event is set to that control output number, the NONE indication (nothing assigned) is displayed.