9. Technical Specifications

9.1Power Range 1000-3000 VA (120 V)

Tower

US 120V Model

UT1A1A010C6

UT1A1A015C6

 

UT1A1A020C6

UT1A1A030C6

Rack-

US 120V Model

UT1A1A010C6R

UT1A1A015C6R

 

UT1A1A020C6R

UT1A1A030C6R

mount (2U)

 

KB2

KB2

 

KB2

KB2

Input

Voltage

 

120 VAC (80 – 144 V)

 

 

Voltage Range

 

+20% to -33%

 

 

Frequency

 

50 / 60 Hz auto sensing

 

 

Power Factor

 

Greater than 0.97

 

 

Topology

True on-line Double conversion Input PF correction

Output

Voltage

 

120 VAC

 

 

Capacity (VA)

1000 VA

1500 VA

 

2000 VA

3000 VA

 

Capacity (W)

700 W

1050 W

 

1400 W

2100 W

 

Frequency

 

50 / 60 Hz auto

sensing *

 

 

Wave Form

 

Sine wave, zero transfer time

 

 

Load Power

 

0.70

 

 

 

Factor

 

 

 

 

 

 

Efficiency

 

Greater than 86%

 

Greater than

 

AC/DC/AC

 

 

 

 

85%

 

Rated Current

8.3 A

12.5 A

 

16.6 A

25 A

 

Overload

125% for 1 min 150% for 10 sec

125% for 1 min

 

Capacity

 

 

 

 

130% for 10

 

 

 

 

 

 

sec

 

Crest Factor

 

3.0 at full load

 

2.5 at full load

Battery

DC Voltage

36 V / 12 V

 

72V / 12 V

 

(Tower & 2U)

9 AH x 3

 

9 AH x 6

 

Backup Time

7 min

6 min

 

6 min

5 min

 

(Tower & 2U)

(full load)

(full load)

 

(full load)

(full load)

 

Interface

RS-232 and USB standard RemotEye II® and EMD option

Physical

Dimensions

16.5”L x 6.0”W x 9.4”H

 

16.7"L x 8.9"W x 14.2"H

 

(Tower)

 

 

 

 

 

 

Dimensions

16.7”L x 16.9”W x 3.5”H

 

25.0"L x 16.9"W x 3.5"H

 

(2U)

 

 

 

 

 

 

Weight

35.6 lbs /

37.4 lbs /

 

68.4 lbs /

72.6 lbs /

 

(Tower/2U)

37.6 lbs

37.6 lbs

 

69.5 lbs

71.5 lbs

 

Line Cord

5-

15P

 

5-20P

L5-30P

 

Receptacles

NEMA 5 - 15 P (6 / 6)

 

Tower - NEMA

5-20 P (12)

 

(Tower/2U)

 

 

 

2U - NEMA 5-15 P (4)

Environ-ment

Operating

 

32 – 104°F (0 – 40°C)

 

 

Temperature

 

 

 

 

 

 

Altitude

 

11500 ft (3500 m) above sea level

 

Warranty

 

Three years on electronics

 

 

 

 

Two years full replacement on battery (See Toshiba warranty policy for full

 

 

details.)

 

 

 

 

Output frequency can hard set at 50 or 60 Hz by installing an optional software upgrade. This upgrade enables the user

to select a fixed output frequency and simultaneously disables the bypass mode.

Standards - Safety:UL-1778, Emissions: FCC Part 15 Class B (1000-2000 VA) FCC Part 15 Class A (3000 VA)

29

Page 54
Image 54
Toshiba user manual Technical Specifications, Power Range 1000-3000 VA 120