9.4Power Range 1000-3000 VA (230 V)

Tower

International

UT1E1E010C6

UT1E1E015C6

 

UT1E1E020C6

UT1E1E030C6

 

230V Model

 

 

 

 

 

Rack-

International

UT1E1E010C6

UT1E1E015C6

 

UT1E1E020C6

UT1E1E030C6RKB

mount (2U)

230V Model

RKB2

RKB2

 

RKB2

2

Input

Voltage

 

230 VAC

(161 – 276 V)

 

 

(International)

 

 

 

 

 

 

Voltage Range

 

+20% to -30%

 

 

(International)

 

 

 

 

 

 

Frequency

 

50 / 60 Hz auto sensing

 

 

Power Factor

 

Greater than 0.97

 

 

Topology

True on-line, Double conversion Input PF correction

Output

Voltage

 

 

230 VAC

 

 

(International)

 

 

 

 

 

 

Capacity (VA)

1000 VA

1500 VA

 

2000 VA

3000 VA

 

Capacity (W)

700 W

1050 W

 

1400 W

2100 W

 

Frequency

 

50 / 60 Hz auto

sensing*

 

 

Wave Form

 

Sine wave, zero transfer time

 

 

Load Power

 

 

0.7

 

 

Factor

 

 

 

 

 

 

Efficiency

 

Greater than 86%

Greater than 85%

 

AC/DC/AC

 

 

 

 

 

 

Rated Current

4.3 A

6.5 A

 

13 A

13 A

 

(International)

 

 

 

 

 

 

Overload

125%

for 1 min., 150% for

10 sec.

125% for 1 min.,

 

Capacity

 

 

 

 

130% for 10 sec.

 

Crest Factor

 

3.0 at full load

 

 

2.5 at full load

Battery

DC Voltage

36 V / 12 V

 

72V

/ 12 V

 

(Tower & 2U)

9 AH x 3

 

9 AH x 6

 

Backup Time

7 min

6 min

 

5 min

5 min

 

(Tower & 2U)

(full load)

(full load)

 

(full load)

(full load)

 

Interface

RS-232 and USB standard

RemotEye II® and

EMD option

Physical

Dimensions

16.5”L x 6.0”W x 9.4”H

 

16.7" L x 8.9" W

16.7" L x 8.9" W x

 

(Tower)

 

 

 

x 14.2" H

14.2" H

 

Dimensions

16.7”L x 16.9”W x 3.5”H

 

25.0"L x 16.9"W

25.0"L x 16.9"W x

 

(2U)

 

 

 

x 3.5"H"

3.5"H"

 

Weight

35.6 lbs /

37.4 lbs /

 

68.4 lbs /

72.6 lbs / 71.5 lbs

 

(Tower/2U)

37.6 lbs

37.6 lbs

 

69.5 lbs

 

 

Line Cord

 

 

IEC 320

 

 

(International)

 

 

 

 

 

 

Receptacles

IEC 320 (4 / 4)

IEC 320 (8 / 4)

IEC 320 (8 / 4)

 

(Tower/2U)

 

 

 

 

 

 

International

 

 

 

 

 

Environ-

Operating

 

32 – 104°F (0 – 40°C)

 

ment

Temperature

 

 

 

 

 

 

Altitude

 

11,500 ft (3500 m) above sea level

 

Warranty

 

Three years on electronics

 

 

 

 

 

Two years full replacement on battery (See Toshiba warranty policy for full details.)

 

 

 

 

 

 

 

Output frequency can hard set at 50 or 60 Hz by installing an optional software upgrade. This upgrade enables the user to select a fixed output frequency and simultaneously disables the bypass mode.

Standards - Safety: EN 62040-1, Emissions: EN 62040-2, Immunity: EN 62040-2 Category C1 (1000-2000VA), EN 62040-2 Category C2 (2000-3000VA

33

Page 58
Image 58
Toshiba user manual Power Range 1000-3000 VA 230, RKB2