1343 PEACH DRIVE
PHONE : 87-6437
Open 8:00am to 7:00pm Closed : every Wednesday
12-19-1994 MON #3001

EO1-11113

TERMINAL CONNECTION TABLE SETTING (Submode 69)

This submode is required for in-line services. Enter the In-line ID No. and the Register No. of each terminal (including the Master Terminal) connected to the in-line cable.

CONDITION

Any time outside a sale

 

 

 

 

OPERATION

Mode Lock: SET and IN-LINE Lamp illuminated

69 [@/FOR]

 

 

In-line ID No. [ST]

 

 

 

Register No. [#]

 

 

 

 

 

 

 

.

 

 

.

 

 

 

 

 

 

 

 

 

 

.

 

 

.

 

 

.

 

 

.

 

 

.

 

 

.

 

 

 

1 to 6 ( NOTES 1 & 2 below)

 

 

 

0 to 999999

 

 

 

 

*

 

 

(NOTE 2 below)

 

 

 

 

 

 

 

 

 

Repeat for other terminals to be connected, including the Master

 

 

Terminal itself. (Max. 6 terminals including the Master Terminal.)

[AT/TL]

*For sequentially programming In-line ID Nos, the In-line ID specification can be skipped.

NOTES:

1. In-line ID No.:

Master Terminal ...

1 (fixed)

 

 

Backup Master Terminal (if connected) ... 2 (fixed)

 

 

Satellite Terminals ...

3 to 6 (max. 4 terminals)

2.The In-line ID No. and Register No. of each terminal to be set here must be the same as those programmed for the terminal in IN-LINE TERMINAL ID SETTING (Submode 77) and STORE/REGISTER NO. SETTING (no submode) in Chapter 6 in the Manager’s Guide for stand-alone level.

3.To delete an individual terminal from the Terminal Connection Table, enter 0 in place of the In-line ID No. in the above operation pattern.

4.To delete the entire Terminal Connection Table once set, operate:

69 [@/FOR] 0 [AT/TL]

5.If a deleting operation (individual or entire deletion) is pertormed, the files occupied by the deleted terminal(s) (such as Floating Cashier File, etc.) is canceled. Therefore, a deleting operation should be performed only when the system is to be re-built or a terminal is to be detached from the system.

ex.): To set a Master Terminal and a Satellite Terminal in the connection table (total of two

terminals in the in-line system):

 

 

Master Terminal

ID No. 1

Register No. 111101

 

 

Satellite Terminal

ID No. 3

Register No. 333303

TEC STORE

 

 

 

Mode Lock: SET/and IN-LINE Lamp illuminated 69 [@/FOR]

1 [ST] 111101 [#] (for the Master Terminal)

3 [ST] 333303 [#] (for the Satellite Terminal)

[AT/TL]

 

P 6 9

01

#111101

03

#333303

 

0014 14:21TM

- 17 -

Page 184
Image 184
Toshiba FS-1650, EO1-11099 Terminal Connection Table Setting Submode, Mode Lock SET and IN-LINE Lamp illuminated, 69 @/FOR