4-way Air Discharge Cassette Type

Installation Manual

„Opening a ceiling and installation of hanging bolts

Consider the piping/wiring after the unit is hung when determining the location of the indoor unit installation and orientation.

After the location of the indoor unit installation has been determined, open the ceiling and install hanging bolts.

The dimensions of the ceiling opening and hanging bolt pitches are given in the outline drawing and the attached installation pattern.

When a ceiling already exists, lay the drain pipe, refrigerant pipe, system interconnection wires, and remote control wires to their connection locations before hanging the indoor unit.

Procure hanging bolts and nuts for installing the indoor unit (these are not supplied).

Hanging bolt

3/8" (M10)

4 pieces

 

 

 

Nut

3/8" (M10)

12 pieces

 

 

 

Using the installation pattern (accessory)

The installation pattern is provided inside the packaging cap.

<For existing ceiling>

Use the installation pattern positioning a ceiling opening and hanging bolts.

<For new ceiling>

Use the installation pattern to position the ceiling opening when hanging a ceiling.

After the hanging bolts have been installed, install the indoor unit.

Hook the four holes in the installation pattern to the panel fixing screws of the indoor unit.

When hanging a ceiling, open the ceiling along the outside dimensions of the installation pattern.

Indoor unit

Treatment of ceiling

The ceiling differs according to structure of building. For details, consult your constructor or interior finish contractor.

In the process after the ceiling board has been removed, it is important to reinforce ceiling foundation (frame) and to keep horizontal level of installed ceiling correctly in order to prevent vibration of ceiling board.

(1)Cut and remove the ceiling foundation.

(2)Reinforce the cut surface of ceiling foundation, and add ceiling foundation for fixing the end of ceiling board.

Installation of hanging bolt

Use 3/8” (M10) hanging bolts (4 pcs, to be local procure). Matching to the existing structure, set pitch according to size in the unit external view as shown below.

New concrete slab

Install the bolts with insert brackets or anchor bolts.

Rubber

(Blade type

(Slide type

Anchor bolt

(Pipe hanging

bracket)

bracket)

anchor bolt)

Steel flame structure

Use existing angles or install new support angles.

Hanging bolt

Hanging bolt Support angle

Existing concrete slab

Use a hole-in anchors, hole-in plugs, or a hole-in bolts.

Panel fixing screw

Installation of ceiling opening and hanging bolt

Hanging bolt

Level

Installation pattern (Accessory) hole

Hanging bracket

EN

– 10 –

10-EN

Page 11
Image 11
Toshiba RAV-SP180UT-UL installation manual „ Opening a ceiling and installation of hanging bolts

RAV-SP180UT-UL specifications

The Toshiba RAV-SP180UT-UL is a cutting-edge commercial air conditioning unit designed to deliver exceptional cooling and heating performance. As part of Toshiba's advanced lineup of air conditioning systems, this model caters to diverse applications such as offices, retail spaces, and other commercial environments, ensuring comfortable conditions year-round.

One of the standout features of the RAV-SP180UT-UL is its powerful inverter technology. This technology enables the unit to adjust its cooling or heating output based on the current load requirements, resulting in significant energy savings and improved efficiency compared to conventional systems. It operates with a high Seasonal Energy Efficiency Ratio (SEER) and a Heating Seasonal Performance Factor (HSPF), making it an environmentally friendly choice for businesses seeking to reduce their carbon footprint.

Another key characteristic of the RAV-SP180UT-UL is its ultra-quiet operation. The unit is designed to minimize noise levels, providing a serene indoor environment that is ideal for workplaces and customer-facing areas. This low-noise performance is achieved through advanced fan engineering and acoustic insulation, ensuring that disruptions to work or leisure activities are kept to a minimum.

The RAV-SP180UT-UL also features flexible installation options, allowing for wall-mounted or ceiling-mounted configurations to suit various spatial requirements. Its compact design means that it can be installed in tight spaces without compromising on performance or aesthetics. The unit is equipped with a remote control for added convenience, enabling users to easily adjust settings, set timers, and switch between modes.

Moreover, the Toshiba RAV-SP180UT-UL is built with durability in mind. It utilizes high-quality materials and components that ensure long-lasting performance, even in demanding environments. The unit is also equipped with advanced filtration systems that enhance indoor air quality by removing dust, allergens, and other contaminants, contributing to a healthier workplace.

In summary, the Toshiba RAV-SP180UT-UL is a reliable and efficient solution for commercial air conditioning needs. Its inverter technology, quiet operation, flexible installation, and emphasis on durability make it a compelling choice for businesses looking to enhance comfort while maintaining energy efficiency. Whether for heating or cooling, this unit delivers consistent performance that meets the demands of modern commercial settings.