„Installation of ceiling panel (Sold separately)

4-way Air Discharge Cassette Type

„Installation of ceiling panel (Sold separately)

Install the ceiling panel according to Installation Manual attached with it after piping/wiring work has completed.

Check that installation of indoor unit and ceiling opening part is correct, and then install it.

REQUIREMENT

Joint the connecting sections of ceiling panel, ceiling surface, ceiling panel and indoor unit closely. Any gap between them will cause air leakage and the generate condensation or water leakage.

Remove the adjust corner caps at the four corners of the ceiling panel, and then install the ceiling panel onto the indoor unit.

Make sure that the claws of the four adjust corner caps are securely fit.

*Improper fitting of the claws may cause water leakage.

„Installation of remote control (Sold separately)

For installation of the wired remote control, follow the Installation Manual attached with the remote control.

Pull out the remote control cord together with the refrigerant pipe or drain pipe.

Be sure to pass the remote control cord through upper side of the refrigerant pipe and drain pipe.

Do not leave the remote control at a place exposed to the direct sunlight and near a stove.

„Wireless remote control

The sensor of indoor unit with wireless remote control can receive a signal by distance within approx. 23’ (7 m). Based upon it, determine a place where the remote control is operated and the installation place.

Operate the remote control, confirm that the indoor unit receives a signal surely, and then install it.

Keep 3’3” (1 m) or more from the devices such as television, stereo, etc.

(Disturbance of image or noise may generate.)

To prevent a malfunction, select a place where is not influenced by a fluorescent light or direct sunlight.

Two or more (Up to 6 units) indoor units with wireless type remote control can be installed in the same room.

W

it

h

in

2

3 ’

(7

m )

Installation Manual

EN

– 12 –