11. Before making a service call

 

 

 

 

 

 

 

 

 

 

 

Problems

Possible causes

Remedies

 

 

 

 

 

 

 

Using a copy function is not

APP-CPU and the LCD type

• When APP-CPU and the LCD type form

 

 

possible.

form may not be appropriate.

are not appropriate the copy function

 

 

 

 

cannot be used.

 

 

Memory data error message

• Something is wrong with the

• Copy to the LCD again. (ref. Chapter 8)

 

 

is displayed.

internal memory.

 

 

 

Disconnection error

• Connection may be broken

• Check the cable and the connector,

 

 

message is displayed when

during communication.

then copy again.

 

 

the copy function is used.

 

 

 

 

"TOSHIBA" screen is

• This phenomenon appears only

• Does not appear after doing copy to the

 

 

momentarily displayed when

once when using copy function

LCD one time(ref. Chapter 8.1).

 

 

using copy function or the

for the first time.

 

 

 

confirmation of the memory

 

 

 

 

information.

 

 

 

 

“----“ is displayed when using

• It occurs when LCD has no

• Copy to the LCD. (ref. Chapter 8)

 

 

the confirmation of the memor

information or communication

 

 

 

information function.

signal between LCD and the

 

 

 

 

inverter is disconnected while

 

 

 

 

copying to the LCD.

 

 

 

German cannot be selected.

APP-CPU version of VFAS1 is

• German can be selected by using

 

 

 

less than V104.

APP-CPU version of VFAS1 is V106 or

 

 

 

 

greater.

 

11-2

Page 35
Image 35
Toshiba RKP004Z instruction manual Before making a service call