8. Operation by a copy function

8. 3 Confirm a memory information

There is no data in LCD, and copy it to LCD at the time of purchase. (Chap.: 8.1)

Push the F3 key on an initial screen and the copy mode screen is displayed.

1 Select the memory saving group that you

 

 

 

 

 

 

 

 

 

Copy Mode

want to confirm using the control dial.

 

 

Group selection

 

 

 

 

 

 

 

 

 

 

 

Memory - A

 

 

 

 

Memory - B

 

 

 

 

 

 

 

 

2 Push the [F4] key.

 

Top

Info

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copy Mode

 

 

 

Group selection

 

 

 

 

 

 

 

 

 

Memory - A

 

 

 

 

Memory - B

 

 

 

 

 

 

Top

Info

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F4

3 Displays detail information in the LCD

 

 

 

 

 

Copy Mode

memory.

 

 

Memory - A

 

 

Inverter information

TypeDisplays VFAS1 or VFPS1.

 

 

 

Type : V FAS1

RatingDisplays voltage and capacity.

 

 

Rating : 200V- 3 . 7 kW

 

 

Version of APP-CPU : v136

Version of APP-CPU

 

CRC code : 6AE3

 

Top

Start

Displays CPU version for the application.

 

 

 

 

 

 

 

 

The total parameter might differ when CPU version is different.

CRC code:

The CRC code is calculated from the communication data. It is detected whether it normally copies to the inverter by agreeing with the CRC in the memory code and the CRC in the copy completion display when copying it to the inverter.