8. Operation. Operationby copy functionin a copy function
The copy function can be used when "Copy" is displayed on the upper part of the F3 key. The copy function works by the latest combination of LCD Remote Keypad (RKP004Z rev.2 or later) with the Inverter version of
|
|
|
|
| Version of |
| |
| Limitation in copy function use | VFAS1 | VFPS1 | ||||
| V134 |
| V136 | V612 | V614 | ||
|
|
|
| ||||
|
|
| or less |
| or more | or less | or more |
| LCD type form | Disabled |
| Disabled | Disabled | Disabled | |
|
| After | Disabled |
| Enabled | Disabled | Enabled |
Moreover, it is not possible to copy | normally in | the following | cases even | if the copy | |||
function can be used. |
|
|
|
|
|
1)It is not possible to copy, when the inverter form differs,.
2)It is not possible to copy to the inverter while driving.
3)It is not possible to copy, when a minimum unit of the frequency is different.
4)It is necessary to reset up the parameters after the copy when copying between the inverters from which capacity differs.
5)It is necessary to reset power supply after the copy when the unit of time differs.
Explanation of the top window |
|
| Display of |
|
| Display of | |||||||
• Display of commands executed: |
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
| ||||
|
| commands |
|
| operating status | ||||||||
“FWD” or “REV” is displayed to indicate the direction of |
|
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
rotation. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Top View Mode |
|
|
|
| ||||||
The operation frequency is displayed in the form of |
|
| FWD 60.0 Hz |
|
|
|
| RUN |
| ||||
“. Hz.” |
|
|
|
| 60.0 Hz |
| |||||||
• Display of operating status: |
|
|
|
|
| ||||||||
“RUN” is displayed during operation. |
|
|
|
|
| ||||||||
“STOP” is displayed during a stop. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Overheat alarm |
|
|
|
|
| |||||
“Trip” is displayed in the event of tripping. |
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Quick |
| Lng |
| Copy |
|
| ||||||
• Display of output frequency: |
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
The operation frequency is displayed in the form of |
|
| F1 |
| F2 |
| F3 |
|
| ||||
“. Hz.” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Display of output frequency | |||||||
• Display of alarm/tripping: |
|
|
|
|
|
| |||||||
|
|
|
|
|
| Display of alarm/tripping | |||||||
If an error or tripping occurs, an error or trip code is displayed. |
|
|
|
|
|
|
|
|
|
| |||
• Display of error/tripping message: |
|
|
| Display of error/tripping message |
If an error or tripping occurs, an error or trip message is displayed
Functions of function keys
F1:Switches between Quick mode and Standard Setting mode
F2 :Brings you to the Language selection window.
F3:Brings you to Copy mode window.