2 Troubleshooting Procedures | 2.3 Power Supply Troubleshooting |
Procedure 3 Power supply connection check
The power supply wiring diagram is shown below:
AC power cord
AC adaptor
AC adaptor cord
System board
Battery
Any of the connectors may be disconnected. Perform Check 1.
Check 1 Disconnect the AC power cord from wall outlet. Check the power cable for breaks. If the power cord is damaged, connect a new AC power cord. If there is no damage, go to Check 2.
Check 2 Make sure the AC adaptor cord and AC power cord are firmly plugged into the DC- IN socket, AC adaptor inlet and wall outlet. If these cables are connected correctly, go to Check 3.
Check 3 Make sure that the
?If the
?If it is not loose, go to Check 4.
Check 4 Use a multi- meter to make sure that the AC adaptor output voltage is close to 15V. If the output is several percent lower than 15V, go to Check 5. If the output is close to 15 V, go to Check 6.
Check 5 Connect a new AC adaptor or AC power cord.
?If the
?If the battery LED does not light, go to Check 6.
Check 6 Make sure the battery pack is installed in the computer correctly. If the battery is properly installed and the battery LED still does not light, go to Procedure 4.
Tecra A3/S2 Series Maintenance Manual |