INDICATORS

How to see the internal states from indicators

There are three indicators that inform of the internal states of the projector. The internal states can be known by how the indicators are lighting. Check the followings, and if there is any problem, stop to use the projector and be sure to unplug the power plug. Then, contact a repair/customer front of Mitsubishi Electric Corporation.

POWER indicator

When the projector is normal:

MENU/EXIT

ENTER

POWER

LAMP indicator

LAMP

TEMP

TEMP(temperature) indicator

POWER LAMP TEMP STATE

REMARK

On in orange

 

Standby state.

 

 

 

 

Blinking in green

 

Lamp standby state.

Power can not be turned "OFF".

Off Off

 

 

 

Power "ON" (usually).

 

On in green

 

 

 

 

 

Blinking in orange

 

Lamp is being cleaned.

Power can not be turned "ON".

 

 

 

If the projector is not normal:

POWER LAMP TEMP

STATE

 

 

The interior of the projector is very hot.

 

 

The intake vent and/or exhaust vent is blocked

 

 

 

with something.

On in

Off

On in red

The projector is used at a very hot place such as

orange

 

 

outlet of heating air.

 

 

The air filter is foul.

 

 

The protection circuit is working, or

 

 

The lamp is not normal.

 

 

(When power is turned off normally, this indication appears,

 

 

and this is not a failure.)

 

On in red

Off

 

On in

 

 

 

green

 

 

 

REMARK

Countermeasure

Remove those things with which the vent is blocked.

Relocate the projector.

Clean the filter.

Press POWER button after POWER

indicator has ceased blinking.

If this operation is repeated several times and the light-source lamp still does not come on, replace the lamp to a new one. Ask the delivery agent of the projector or a repair/customer front of Mitsubishi Electric Corporation about purchase of the lamp.

 

 

 

 

 

 

 

 

Indicating replacement of the lamp (Used about 1000

 

 

 

 

 

 

 

 

hours* in total; Power is "ON".)

 

 

Blinking

 

 

 

 

 

 

 

 

Indicating replacement of the lamp (Used about 1000

 

 

in red

 

 

 

Off

hours* in total; Power is "OFF".)

 

 

 

 

 

 

 

On in

 

 

 

Indicating replacement of the lamp (Used about 1500

orange On in red

 

 

hours* in total)

Replace the light-source lamp to a new one. Purchase a light-source lamp from the delivery agent of the projector.

Kensington Lock

This projector has a Kensington Security Standard connector for use with a Kensington MicroSaver Security System. Refer to the information that came with the Kensington System for instructions on how to use it to secure the projector. Please contact to Kensington Technology Group as shown below.

Kensington Technology Group

2855 Campus Drive

San Mateo, CA 94403, U.S.A.

Phone : (650)572-2700 Fax : (650)572-9675

38

Page 38
Image 38
Toshiba TDP-MT500 owner manual Indicators, Power Lamp Temp State, Remark