13.7.2

Monitor Parameters

 

 

 

 

 

 

 

 

 

 

 

Parameter

Bit

Function

Bank

Mask

Adjustment Range

Multiplier

 

 

 

 

 

 

 

0005

word

Output frequency monitor

0

FFFF

0.00 ~ 400.00Hz

0.01

0006

0

Run stop status

0

0: Stopped

 

 

 

 

 

1: Running

 

 

1

Reserved

 

 

 

 

2

Forward reverse status

 

 

0: Reverse

 

 

 

 

 

 

1: Forward

 

 

3

Accel / decel #1 / #2 selection

 

 

0: Accel / decel #1

 

 

 

status

 

 

1: Accel / decel #2

 

 

 

 

 

 

 

 

4

Reserved

 

 

 

 

5

Reserved

 

 

 

 

6

Reserved

 

 

 

 

7

Jog mode status

 

 

0: Normal (accel /

 

 

 

 

 

 

decel mode)

 

 

 

 

 

 

1: Jog mode

 

 

8

Feedback enable status

 

 

0: Feedback invalid

 

 

 

 

 

 

1: Feedback valid

 

 

9

Compulsory DC injection

 

 

0: DC injection braking

 

 

 

braking mode

 

 

inactive

 

 

 

 

 

 

1: DC injection braking

 

 

 

 

 

 

active

 

 

A

Fundamental parameter

 

 

0: V/F #1

 

 

 

switching

 

 

1: V/F #2

 

 

 

 

 

 

 

 

B

Coast stop command status

 

 

0: Normal

 

 

 

 

 

 

1: Coast to stop

 

 

C

Emergency off command

 

 

0: Normal

 

 

 

 

 

 

1: Emergency off

 

 

D

Reserved

 

 

 

 

E

Reserved

 

 

 

 

F

Reserved

 

 

 

0007

word

Output current monitor

0

00FF

0 ~ 255%

1

0008

word

Output voltage monitor (Note

0

FFFF

0 ~ 232%

0.1

 

 

1)

 

 

 

 

0009

word

IV terminal analog input value

0

FFFF

0000 ~ FFFF (0% ~

1

 

 

 

 

 

100%)

 

000A

word

RX terminal analog input

0

FFFF

0000 ~ 7FFF (-100% ~

1

 

 

value

 

 

0%), 7FFF ~ FFFF

 

 

 

 

 

 

(0% ~ 100%)

 

000B

word

Frequency command monitor

0

FFFF

0000 9C40

0.01

 

 

 

 

 

(0.00 400.00 Hz)

 

000C

word

Input voltage monitor (Note 1)

0

FFFF

0 ~ 255%

0.1

000D

word

Input terminal status monitor

0

FFFF

Refer to Table 5 (page

 

 

 

 

 

67)

 

000E

low

Output terminal status

0

00FF

Refer to Table 6 (page

 

byte

monitor

 

 

67)

 

 

high

Inverter Status 2

 

FF00

 

 

 

byte

 

 

 

 

 

000F

word

Inverter Status 1

0

FFFF

Refer to Table 7 (page

 

 

 

 

 

68)

 

0010

word

Present trip

0

00FF

 

0011

high

4th Past trip (most recent)

0

7F00

 

 

byte

 

 

 

 

 

 

low

3rd past trip

 

007F

Refer to section

 

 

byte

 

 

 

13.7.16 for fault codes

 

65