Table 10: Output Terminal Selections (RCH, LOW, FL, OUT relay contacts)
Setting | Data | Function | Setting | Data | Function | |
Value | (Hex) | Value | (Hex) | |||
|
| |||||
|
|
|
|
|
| |
0 | 0000 | Lower limit frequency | 32 | C5B7 | Executing emergency off | |
1 | 0100 | /Lower limit frequency | 33 | CDB7 | /Executing emergency off | |
2 | 0200 | Upper limit frequency | 34 | B5BB | Executing retry | |
3 | 0300 | /Upper limit frequency | 35 | BDBB | /Executing retry | |
4 | 0400 | Low speed signal | 36 | D5CF | Pattern run switching output | |
5 | 0500 | /Low speed signal | 37 | DDCF | /Pattern run switching output | |
6 | 0600 | Accel/decel complete | 38 | D5D8 | PID deviation limit | |
7 | 0700 | /Accel/decel complete | 39 | DDD8 | /PID deviation limit | |
8 | 0800 | Selected speed reach signal | 40 | C5BB | Run/stop | |
9 | 0900 | /Selected speed reach signal | 41 | CDBB | /Run/stop | |
10 | 0A00 | Fault | 42 | 1400 | Severe fault (armature short, load- | |
|
|
|
|
| end short, open phase, output | |
|
|
|
|
| error, earth fault) | |
11 | 0B00 | /Fault | 43 | 1500 | /Severe fault (armature short, load- | |
|
|
|
|
| end short, open phase, output | |
|
|
|
|
| error, earth fault) | |
12 | 0C00 | Fault other than earth fault or | 44 | 1600 | ||
|
|
|
| overcurrent, overvoltage) | ||
13 | 0D00 | /Fault other than earth fault or | 45 | 1700 | ||
|
|
|
| overcurrent, overvoltage) | ||
14 | 95B5 | Overcurrent | 46 | E5D8 | Commercial power / inverter | |
|
|
|
|
| switching output #1 | |
15 | 9DB5 | /Overcurrent | 47 | EDD8 | /Commercial power / inverter | |
|
|
|
|
| switching output #1 | |
16 | 85C5 | Inverter overload | 48 | F5D8 | Commercial power / inverter | |
|
|
|
|
| switching output #2 | |
17 | 8DC5 | /Inverter overload | 49 | FDD8 | /Commercial power / inverter | |
|
|
|
|
| switching output #2 | |
18 | 95C5 | Motor overload | 50 | 85C0 | Fan ON/OFF | |
19 | 9DC5 | /Motor overload | 51 | 8DC0 | /Fan ON/OFF | |
20 | D5C5 | Overheat | 52 | F5B6 | Executing JOG | |
21 | DDC5 | /Overheat | 53 | FDB6 | /Executing JOG | |
22 | A5B4 | Overvoltage | 54 | 1800 | Local/remote operation | |
23 | ADB4 | /Overvoltage | 55 | 1900 | /Local/remote operation | |
24 | E5B4 | Undervoltage alarm | 56 | A5D1 | Cumulative timer alarm | |
25 | EDB4 | /Undervoltage alarm | 57 | ADD1 | /Cumulative timer alarm | |
26 | 85B5 | Undercurrent alarm | 58 | 1A00 | Communication error alarm | |
27 | 8DB5 | /Undercurrent alarm | 59 | 1B00 | /Communication error alarm | |
28 | 85D1 | Overtorque alarm | 60 | A5B6 | F/R | |
29 | 8DD1 | /Overtorque alarm | 61 | ADB6 | /F/R | |
30 | E5BB | Braking resistor OL | 62 | 1E00 | Run preparation complete | |
31 | EDBB | /Braking resistor OL | 63 | 1F00 | /Run preparation complete |
74