13.7.9 | Protection Function Parameters |
|
| ||||||
|
|
|
|
|
|
|
|
| |
Parameter |
| Function / Title | Bank | Mask | Adjustment Range |
| Multiplier | ||
|
|
|
|
|
|
|
|
| |
011F | DYNAMIC BRAKING | 0 / 1 | 0003 | 0000: no dynamic braking | (0) | | |||
| SELECTION |
|
| 0001: with dynamic braking, no DBR |
| ||||
|
|
|
|
|
|
| overload trip | (1) |
|
|
|
|
|
|
|
| 0003: with dynamic braking and DBR |
| |
|
|
|
|
|
|
| overload trip | (2) |
|
0120 |
|
| BRAKING | 0 / 1 | FFFF | 000A ∼ 2710 (1.0 ∼ 1000) |
| 0.1 | |
| 2 |
| RESISTOR VALUE |
|
|
|
|
| |
0121 |
| BRAKING | 0 / 1 | FFFF | 0001 ∼ EA60 (0.01 ∼ 600.00) |
| 0.01 | ||
|
|
| RESISTOR POWER |
|
|
|
|
| |
|
|
| RATING |
|
|
|
|
| |
0122 |
| OVERVOLTAGE STALL | 0 / 1 | 0004 | 0000: ON | (0) | | ||
| PROTECTION |
|
| 0004: OFF | (1) |
| |||
0123 | DC INJECTION START | 0 / 1 | FFFF | 0000 ∼ 2EE0 (0.00 ∼ 120.00) |
| 0.01 | |||
| FREQUENCY |
|
|
|
|
| |||
0124 | Other | DC INJECTION | 0 / 1 | 00FF | 0000 ∼ 0064 (0 ∼ 100) |
| 1 | ||
| CURRENT |
|
|
|
|
| |||
| than |
| MAGNITUDE |
|
|
|
|
| |
0125 | 0 |
| DC INJECTION | 0 / 1 | 00FF | 0000 ∼ 0064 (0.0 ∼ 10.0) |
| 0.1 | |
|
|
|
| TIME |
|
|
|
|
|
0126 | FWD/REV | DC | 0 / 1 | 0040 | 0000: OFF | (0) | | ||
| INJECTION PRIORITY |
|
| 0040: ON | (1) |
| |||
| CTRL |
|
|
|
|
|
| ||
0127 | MOTOR SHAFT | 0 / 1 | 0080 | 0000: OFF | (0) | | |||
| STATIONARY CTRL |
|
| 0080: ON | (1) |
| |||
0128 | EMERGENCY OFF MODE | 0 / 1 | 0030 | 0000: Coast stop | (0) | | |||
| SELECTION |
|
| 0010: Decelerated stop | (1) |
| |||
|
|
|
|
|
|
| 0020: DC injection stop | (2) |
|
0129 | 2 |
| EMERGENCY OFF | 0 / 1 | 00FF | 0000 ∼ 0064 (0.0 ∼ 10.0) |
| 0.1 | |
|
| DC INJECTION |
|
|
|
|
| ||
|
|
| TIME |
|
|
|
|
| |
012A | NUMBER OF RETRY | 0 / 1 | 00FF | 0000 ∼ 000A (0 ∼ 10) |
| 1 | |||
| ATTEMPTS |
|
|
|
|
| |||
012B | Other | TIME BETWEEN | 0 / 1 | 00FF | 0000 ∼ 0064 (0.0 ∼ 10.0) |
| 0.1 | ||
| than |
| RETRY |
|
|
|
|
| |
| 0 |
| ATTEMPTS |
|
|
|
|
| |
012C | REGENERATION POWER | 0 / 1 | 0008 | 0000: OFF | (0) | | |||
|
|
| 0008: ON | (1) |
| ||||
012D | 1 |
| REGENERATION | 0 / 1 | 00FF | 0000 ∼ 00FA (0.0 ∼ 25.0) |
| 0.1 | |
|
|
|
|
|
|
| |||
|
|
| TIME |
|
|
|
|
| |
012E | 0 / 1 | 0018 | 0000: OFF | (0) | | ||||
| SPEED SEARCH) |
|
| 0008: On power failure | (1) |
| |||
|
|
|
|
|
|
| 0010: On ST make/break | (2) |
|
|
|
|
|
|
|
| 0018: Both (1) and (2) | (3) |
|
012F | ELECTRONIC THERMAL | 0 / 1 | 00FF | 000A ∼ 0064 (10 ∼ 100) |
| 1 | |||
| PROTECT LVL #1 |
|
|
|
|
| |||
0130 | OVERLOAD REDUCTION | 0 / 1 | FFFF | 0000 ∼ 0BB8 (0.00 ∼ 30.00) |
| 0.01 | |||
| START FREQ |
|
|
|
|
| |||
0131 | MOTOR 150% OVERLOAD | 0 / 1 | 00FF | 0001 ∼ 00F0 (10 ∼ 2400) |
| 10 | |||
| TIME LIMIT |
|
|
|
|
| |||
0132 | OVERLOAD SELECTION | 0 / 1 | 0030 | 0000: with motor overload trip, |
| | |||
|
|
|
|
|
|
| without | (0) |
|
|
|
|
|
|
|
| 0010: with motor overload trip and |
|
|
|
|
|
|
|
|
| (1) |
| |
|
|
|
|
|
|
| 0020: without |
|
|
|
|
|
|
|
|
| overload trip | (2) |
|
|
|
|
|
|
|
| 0030: with |
|
|
|
|
|
|
|
|
| overload trip | (3) |
|
79