13.7.6

Terminal Selection Parameters

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

Function / Title

Bank

Mask

 

Adjustment Range

 

Multiplier

 

 

 

 

 

 

 

 

0044

INPUT TERMINAL

0 / 1

0001

0000: Standard functions

(0)

 

SELECTION

 

 

0001: Individual selections

(1)

 

0045

 

“R” INPUT TERMINAL

0 / 1

FFFF

0000

FFFF (0 54)

 

 

 

FUNCTION

 

 

 

 

 

 

0046

 

“S1” INPUT

 

 

Refer to Table 9 (page 73)

 

 

 

 

TERMINAL FUNCTION

 

 

 

 

 

 

0047

 

“S2” INPUT

 

 

 

 

 

 

 

 

TERMINAL FUNCTION

 

 

 

 

 

 

0048

 

“S3” INPUT

 

 

 

 

 

 

 

 

TERMINAL FUNCTION

 

 

 

 

 

 

0049

 

“S4” INPUT

 

 

 

 

 

 

 

 

TERMINAL FUNCTION

 

 

 

 

 

 

004A

 

“F” INPUT TERMINAL

 

 

 

 

 

 

 

1

FUNCTION

 

 

 

 

 

 

004B

“RES” INPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TERMINAL FUNCTION

 

 

 

 

 

 

004C

 

“ST” INPUT

 

 

 

 

 

 

 

 

TERMINAL FUNCTION

 

 

 

 

 

 

004D

 

“S5” INPUT

 

 

 

 

 

 

 

 

TERMINAL FUNCTION

 

 

 

 

 

 

004E

 

“S6” INPUT

 

 

 

 

 

 

 

 

TERMINAL FUNCTION

 

 

 

 

 

 

004F

 

“S7” INPUT

 

 

 

 

 

 

 

 

TERMINAL FUNCTION

 

 

 

 

 

 

0050

 

POTENTIAL TERMINAL

 

 

 

 

 

 

 

 

FUNCTION

 

 

 

 

 

 

0051

R,S1-S7 TERMINAL

0 / 1

00FF

0001

0064 (1 100)

 

1

 

RESPONSE TIME

 

 

 

 

 

 

0052

F INPUT TERMINAL

0 / 1

00FF

0001

0064 (1 100)

 

1

 

RESPONSE TIME

 

 

 

 

 

 

0053

RES INPUT TERMINAL

0 / 1

00FF

0001

0064 (1 100)

 

1

 

RESPONSE TIME

 

 

 

 

 

 

0054

ST INPUT TERMINAL

0 / 1

00FF

0001

0064 (1 100)

 

1

 

RESPONSE TIME

 

 

 

 

 

 

0055

“RCH” CONTACTS

0 / 1

FFFF

0 FFFF (0 63)

 

 

FUNCTION

 

 

Refer to Table 10 (page 74)

 

 

0056

“RCH” CONTACTS DELAY

0 / 1

00FF

0001

0064 (1 100)

 

1

 

TIME

 

 

 

 

 

 

0057

“RCH” CONTACTS HOLD

0 / 1

00FF

0001

0064 (1 100)

 

1

 

TIME

 

 

 

 

 

 

0058

“LOW” CONTACTS

0 / 1

FFFF

0 FFFF (0 63)

 

 

FUNCTION

 

 

Refer to Table 10 (page 74)

 

 

0059

“LOW” CONTACTS DELAY

0 / 1

00FF

0001

0064 (1 100)

 

1

 

TIME

 

 

 

 

 

 

005A

“LOW” CONTACTS HOLD

0 / 1

00FF

0001

0064 (1 100)

 

1

 

TIME

 

 

 

 

 

 

005B

“FL” CONTACTS FUNCTION

0 / 1

FFFF

0 FFFF (0 63)

 

 

 

 

 

 

Refer to Table 10 (page 74)

 

 

005C

“FL” CONTACTS DELAY

0 / 1

00FF

0001

0064 (1 100)

 

1

 

TIME

 

 

 

 

 

 

005D

“FL” CONTACTS HOLD

0 / 1

00FF

0001

0064 (1 100)

 

1

 

TIME

 

 

 

 

 

 

005E

“OUT” CONTACTS

0 / 1

FFFF

0 FFFF (0 63)

 

 

FUNCTION

 

 

Refer to Table 10 (page 74)

 

 

005F

“OUT” CONTACTS DELAY

0 / 1

00FF

0001

0064 (1 100)

 

1

 

TIME

 

 

 

 

 

 

0060

“OUT” CONTACTS HOLD

0 / 1

00FF

0001

0064 (1 100)

 

1

 

TIME

 

 

 

 

 

 

71