Parameter | Bit | Function | Bank | Mask | Adjustment Range | Multiplier |
|
|
|
|
|
|
|
0012 | high | 2nd past trip | 0 | 7F00 |
| |
| byte |
|
|
|
|
|
| low | 1st past trip (oldest) |
| 007F |
|
|
| byte |
|
|
|
|
|
0013 | word | 0 | FFFF | 0000 ∼ 9C40 | 0.01 | |
|
| frequency |
|
| (0.00 ∼ 400.00 Hz) |
|
0014 | word | 0 | FFFF | 0000 ∼ 9C40 | 0.01 | |
|
| frequency |
|
| (0.00 ∼ 400.00 Hz) |
|
0015 | word | Torque current monitor | 0 | FFFF | (Note 2) | 0.01 |
0016 | low | Excitation current monitor | 0 | 00FF | 00 ∼ FF (0 ~ 255%) | 1 |
| byte |
|
|
|
|
|
| high | Reserved | | | | |
| byte |
|
|
|
|
|
0017 | word | PID feedback value | 0 | FFFF | (Note 2) | 0.02 |
0018 | word | Motor overload ratio | 0 | FFFF | 0 ~ 65535 | 100/65535 |
0019 | word | Inverter overload ratio | 0 | FFFF | 0 ~ 65535 | 100/65535 |
001A | word | DBR overload ratio | 0 | FFFF | 0 ~ 65535 | 100/65535 |
001B | word | Input power (%) | 0 | FFFF | 0 ~ 6553.5 | 0.1 |
001C | word | Input power (kW) | 0 | FFFF | (Note 3) |
|
001D | word | Output power (%) | 0 | FFFF | (Note 2) | 0.1 |
001E | word | Output power (kW) | 0 | FFFF | (Note 2, Note 3) |
|
001F | word | RR input | 0 | FFFF | 0 ~ 65535 | 100/65535 |
0020 | | Reserved | | | | |
0021 | | Reserved | | | | |
0022 | | Reserved | | | | |
0023 | low | Inverter typeform monitor | 0 | 00FF | Refer to Table 8 (page | |
| byte |
|
|
| 68) |
|
| 8 | Input / output power units | 0 | 0100 | 0: 0.01kW | |
|
|
|
|
| 1: 0.1kW |
|
| 9,A | Command mode status | 0 | 0600 | 00: terminal | |
|
|
|
|
| 01: panel |
|
|
|
|
|
| 10: option |
|
|
|
|
|
| 11: RS232C |
|
| B,C | Frequency mode selection | 0 | 1800 | 00: terminal | |
|
| status |
|
| 01: panel |
|
|
|
|
|
|
| |
|
|
|
|
| 10: option |
|
|
|
|
|
| 11: RS232C |
|
| D,E,F | Reserved | | | | |
0024 | | Reserved | | | | |
0025 | word | Output current (amps) | | FFFF | 0.0 ~ 6553.5 A | 0.1 |
(Note 1) .... These monitor voltage units are not affected by the setting of VOLTAGE UNITS SELECTION in
GROUP:UTILITY PARAMETERS; they are always in units of %.
(Note 2) .... These parameters use signed data (data values larger than 7FFFH are negative). If the parameter data is
8000H or larger, the actual value can be obtained by: actual value = - [FFFFH - (parameter data) + 1].
(Note 3) .... If the input / output power units data is 0, the monitored data is in 0.01kW units, and the multiplier is 0.01.
If the input / output power units data is 1, the monitored data is in 0.1kW units, and the multiplier is 0.1. These values are automatically set according to the inverter’s capacity.