15 – Cabinet Installation (continued)

5-3 Placement

Use the casters to move the UPS system for a short distance over

2 a level, smooth, stable surface. Do not attempt to use the casters to move the UPS system over longer distances. The UPS system should be moved close to its final installation location inside its shipping container before it is unpacked from the shipping

container. Use a mechanical device of sufficient capacity to move

3 the shipping container. Warning: The UPS system could tip if it is moved over an unstable surface. Be extremely careful when moving the UPS system. Push the UPS system from the front or rear, not from the sides.

4

 

 

Position the UPS system in a structurally sound area with a

 

 

 

 

level floor that is able to bear the weight of the UPS system,

 

 

 

any external battery cabinets and other equipment that will be

 

 

 

 

 

 

installed nearby. The installation site should also have a dedicated

5

 

 

AC circuit available that is compatible with the UPS system’s

 

 

input requirements. (See the Section 12 – Specifications for

 

 

 

 

 

 

more information about input requirements and floor loading

 

 

 

requirements.) The UPS system must be installed in a clean,

 

 

 

 

 

 

secure environment with a relative humidity less than 90% (non-

6

 

 

condensing). Operate the UPS system at indoor temperatures

 

 

between 17° C and 29° C (62° F and 84° F). Prevent damage to

 

 

 

 

 

 

cabling by using suitable protective conduits. In order to maintain

 

 

 

proper airflow and service access, you must maintain the following

 

 

 

clearances:

7

 

 

• At least 100 cm (39.4”) clearance in front of the UPS system.

At least 50 cm (19.7”) clearance behind the UPS system.

At least 50 cm (19.7”) clearance above the UPS system.

8

Warning: The cooling fans circulate air from front to back. Do not

 

use any air conditioning or fan that blows air directly toward the

rear of the UPS system.

After moving the UPS system to its final location, lock the casters

9

 

and use the levelers

 

to stabilize the cabinet. Ensure that all

four levelers make firm contact with the floor.

10

Attach the balance supports on either side of UPS using 4 bolts.

1

50 cm (19.7 in.)

50 cm (19.7 in.)

100 cm (39.4 in.)

2

B

A

3

 

11

Caution: The UPS system may topple over in unexpected circumstances if both balance supports are not properly installed.

For emergency use, install a fire extinguisher rated for energized electrical equipment fires (Class C rating or exact equivalent, with

12 a non-conductive extinguishing agent) near the UPS system.

13

5

14

10

12-212-93-3141.indb 10

12/28/2012 11:17:21 AM

Page 10
Image 10
Tripp Lite SU120KX2 owner manual Placement, Rear of the UPS system

SU120KX2 specifications

The Tripp Lite SU120KX2 is an advanced uninterruptible power supply (UPS) that provides reliable backup power and surge protection for critical devices. Engineered for small and medium-sized businesses, this UPS is ideal for safeguarding sensitive electronics such as servers, network devices, and telecommunications equipment.

One of the standout features of the SU120KX2 is its impressive 1200VA power capacity. This allows it to deliver significant run time during power outages, ensuring that your equipment remains operational until power is restored or until you can safely shut down your systems. With a pure sine wave output, this UPS simulates utility power, providing stable voltage and frequency to connected devices. This is particularly important for equipment that is sensitive to power fluctuations, as it helps to maintain optimal performance and longevity.

The SU120KX2 is equipped with multiple battery and surge protected outlets, providing flexibility for connecting various devices. It includes USB and serial connectivity options for easy communication with connected equipment, enabling monitoring of battery status and power conditions. An LCD screen provides real-time information on battery level, load capacity, and input/output voltage, ensuring users are informed about the status of their power supply.

Another notable feature is the built-in automatic voltage regulation (AVR). This technology helps to stabilize input voltage levels, correcting minor fluctuations without switching to the battery, thereby extending the life of the battery while ensuring your devices receive consistent and clean power. Furthermore, the SU120KX2 includes advanced battery management features that optimize battery performance and provide notifications for battery replacement when necessary.

For added convenience, the Tripp Lite SU120KX2 offers hot-swappable battery capabilities, allowing users to replace batteries without shutting down connected devices. This ensures that your critical operations are not interrupted, making it an ideal choice for businesses that cannot afford downtime.

Overall, the Tripp Lite SU120KX2 combines robust performance with reliable protection, making it a perfect solution for businesses looking to secure their electronic infrastructure against power disturbances. With its manageable size, advanced features, and user-friendly interface, the SU120KX2 stands out as a dependable UPS that meets the needs of various applications while ensuring the integrity and availability of your critical systems.