12 – Important Safety Instructions

2

3

4

SAVE THESE INSTRUCTIONS

All sections of this manual contains instructions and warnings that should be followed during the installation and operation of the UPS systems described in this manual. Read all instructions thoroughly before attempting to move, install or operate the UPS systems described in this manual. Failure to comply may invalidate the warranty and cause property damage and/or personal injury.

Location Warnings

Install the UPS system in a controlled indoor environment, away from moisture, temperature extremes, flammable liquids and gasses, conductive contaminants, dust and direct sunlight.

Install the UPS system in a level, structurally sound location.

The UPS system is extremely heavy; be extremely careful when moving or lifting the unit.

Operate the UPS system at indoor temperatures between 32° F and 104° F (0° C and 40° C) only. For best results, maintain indoor temperatures between 62° F and 84° F (17° C and 29° C).

Leave adequate space around all sides of the UPS system for proper ventilation. Do not block, cover or insert objects into the external ventilation

5

openings of the cabinet.

6

7

8

Do not place any object on the unit, especially containers of liquid.

Do not mount the unit with its front or rear panel facing down (at any angle). Mounting in this manner will seriously inhibit the unit’s internal cooling, eventually causing product damage not covered under warranty.

Do not install the UPS system near magnetic storage media, as this may result in data corruption. Keep all recorded magnetic media a minimum of 60 cm (24 inches) away from the UPS system.

Do not attempt to stack the UPS system. Attempting to stack the UPS system may cause permanent damage and create a potential for serious personal injury.

The casters are designed for minor position adjustments within the final installation area only. The casters are not designed for moving the UPS system over longer distances.

The casters are not designed to provide long-term support for the UPS system after final installation. Use the levelers to provide long-term support.

When moving the UPS system, push from the front or rear, not from the sides.

Do not attempt to unpack or move the UPS system without assistance.

9

Connection Warnings

• The power supply for the UPS system must be 3-phase rated in accordance with the equipment nameplate. It also must be suitably

grounded and wired according to all applicable national and local electrical wiring standards, codes and regulations.

The UPS system contains hazardous high voltages that have the potential to cause personal injury or death from electric shock.

The UPS system has its own energy source (battery – internal and/or external). The output terminals may be live even when the UPS system is

10 not connected to an AC supply.

If the UPS system receives power from a motor-powered AC generator, the generator must provide clean, filtered, computer-grade output.

Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a

11

flammable anesthetic mixture with air, oxygen or nitrous oxide.

The UPS system is designed to power modern computer loads and associated peripheral devices. Do not use the UPS system to power pure inductive or capacitive loads.

12

13

14

Input and output wiring should be performed by trained, qualified electricians only.

Due to high leakage current, a proper earth ground connection is essential before connecting the AC supply.

Isolate the UPS system before working on the circuit. An easily accessible disconnect device should be incorporated in the fixed wiring. The disconnect device must disconnect all line conductors simultaneously when opened.

4

12-212-93-3141.indb 4

12/28/2012 11:16:52 AM

Page 4
Image 4
Tripp Lite SU120KX2 owner manual Important Safety Instructions, Location Warnings, Connection Warnings

SU120KX2 specifications

The Tripp Lite SU120KX2 is an advanced uninterruptible power supply (UPS) that provides reliable backup power and surge protection for critical devices. Engineered for small and medium-sized businesses, this UPS is ideal for safeguarding sensitive electronics such as servers, network devices, and telecommunications equipment.

One of the standout features of the SU120KX2 is its impressive 1200VA power capacity. This allows it to deliver significant run time during power outages, ensuring that your equipment remains operational until power is restored or until you can safely shut down your systems. With a pure sine wave output, this UPS simulates utility power, providing stable voltage and frequency to connected devices. This is particularly important for equipment that is sensitive to power fluctuations, as it helps to maintain optimal performance and longevity.

The SU120KX2 is equipped with multiple battery and surge protected outlets, providing flexibility for connecting various devices. It includes USB and serial connectivity options for easy communication with connected equipment, enabling monitoring of battery status and power conditions. An LCD screen provides real-time information on battery level, load capacity, and input/output voltage, ensuring users are informed about the status of their power supply.

Another notable feature is the built-in automatic voltage regulation (AVR). This technology helps to stabilize input voltage levels, correcting minor fluctuations without switching to the battery, thereby extending the life of the battery while ensuring your devices receive consistent and clean power. Furthermore, the SU120KX2 includes advanced battery management features that optimize battery performance and provide notifications for battery replacement when necessary.

For added convenience, the Tripp Lite SU120KX2 offers hot-swappable battery capabilities, allowing users to replace batteries without shutting down connected devices. This ensures that your critical operations are not interrupted, making it an ideal choice for businesses that cannot afford downtime.

Overall, the Tripp Lite SU120KX2 combines robust performance with reliable protection, making it a perfect solution for businesses looking to secure their electronic infrastructure against power disturbances. With its manageable size, advanced features, and user-friendly interface, the SU120KX2 stands out as a dependable UPS that meets the needs of various applications while ensuring the integrity and availability of your critical systems.