Tripp Lite SU120KX2 owner manual Table of Contents

Models: SU120KX2

1 232
Download 232 pages 35.53 Kb
Page 2
Image 2

1Table of Contents

2

3

4

5

6

1

Introduction

3

 

 

 

 

 

2

Important Safety Instructions

4

 

 

 

 

 

3

Control Panel Features

6

 

 

 

 

 

4

Front and Rear Panel Features

7

 

 

 

 

 

5

Cabinet Installation

9

 

5-1

Preparation

9

 

 

 

 

 

5-2

Unpacking

9

 

 

 

 

 

5-3

Placement

10

 

 

 

 

 

6

Wiring

11

 

6-1

Wiring Warnings

11

 

 

 

 

 

6-2

Wiring Preparation

11

 

 

 

 

 

6-3

UPS System Terminal Block Diagram

12

 

 

 

 

 

6-4

External Battery Cabinet Wiring Diagrams

12

 

 

 

 

 

6-5

Electrical and Cable Data

13

 

 

 

 

 

6-6

External Battery Cabinet Wiring

14

 

 

 

 

 

6-7

AC Input/Output Wiring (Single UPS—SUS)

14

 

 

 

 

6-8

AC Input/Output Wiring (Parallel Configuration—2x MUS) 15

 

 

 

 

6-9

AC Input/Output Wiring (Parallel Configuration—4x MUS) 16

 

9

Power Module Status and Replacement

29

 

9-1

Power Module Features and Status

29

 

 

 

 

 

9-2

Preliminary Replacement Checklist

29

 

 

 

 

 

9-3

Replacement Procedure

29

 

10

Display and Configuration

30

 

10-1

Control Panel Diagram

30

 

 

 

 

 

10-2

Display Hierarchy

30

 

 

 

 

 

10-3

Default Display

31

 

 

 

 

 

10-3-1

Status Display

31

 

 

 

 

 

10-4

Main Menu

34

 

 

 

 

 

10-5

UPS Setup

36

 

 

 

 

10-5-1 Bypass Setup

37

 

 

 

 

10-5-2 Output Setup

38

 

 

 

 

 

10-5-3

Battery Setup

40

 

 

 

 

10-5-4 Charger Setup

43

 

 

 

 

 

10-5-5

Parallel Setup

44

 

 

 

 

10-5-6 Control & Test Setup

45

 

 

 

 

10-5-7 Local Setup

47

 

 

 

 

 

10-6

Maintenance

50

 

7

8

9

10

11

12

13

14

 

 

 

 

 

11

Communications

52

 

7

Operating Modes

17

 

 

 

 

 

11-1

Communications Interfaces

52

 

7-1

Online (Normal) Mode (Single UPS—SUS)

17

 

 

 

 

 

 

 

 

 

 

 

11-2

SNMPWEBCARD Slot

52

 

 

 

 

 

 

 

7-2

Battery Backup Mode (Single UPS—SUS)

17

 

 

 

 

 

 

 

 

 

 

 

11-3

Input Dry Contact Interface

52

 

 

 

 

 

 

 

7-3

Auto Bypass Mode (Single UPS—SUS)

17

 

 

 

 

 

 

 

 

 

 

 

11-4

Remote Emergency Power Off (EPO) Circuit Diagram

53

 

 

 

 

 

 

 

7-4

Manual Bypass Mode (Single UPS—SUS)

17

 

 

 

 

 

 

 

 

 

 

 

11-5

Auxiliary Dry Contact Input Circuit Diagram

53

 

 

 

 

 

 

 

7-5

On-line (Normal) Mode (Parallel UPS—MUS)

18

 

 

 

 

 

 

 

 

 

 

 

11-6

External Battery Cabinet Temperature Inputs

53

 

 

 

 

 

 

 

7-6

Battery Backup Mode (Parallel UPS—MUS)

18

 

 

 

 

 

 

 

 

 

 

 

11-7

External Battery Status Input

53

 

 

 

 

 

 

 

7-7

Auto Bypass Mode (Parallel UPS—MUS)

18

 

 

 

 

 

 

 

 

 

 

 

11-8

Output Dry Contact Interface Detail

54

 

 

 

 

 

 

 

7-8

Manual Bypass Mode (Parallel UPS—MUS)

19

 

 

 

 

 

 

 

 

 

 

 

11-9

Output Dry Contact Circuit Diagram

55

 

 

 

 

 

 

 

7-9

External Maintenance Bypass (Parallel UPS—MUS)

19

 

 

 

 

 

 

 

 

 

 

 

11-10

RS-232 Serial Port Circuit Diagram

55

 

 

 

 

 

 

 

8

Start-Up, Shutdown and Bypass

20

 

 

 

 

 

 

 

 

 

 

 

11-11

Parallel Configuration Port

55

 

8-1

Control Panel and Breaker Diagrams

20

 

 

 

 

 

 

 

 

 

12

Specifications

56

 

 

 

 

 

 

 

8-2

Preliminary Checklist (Single UPS—SUS)

20

 

 

 

 

 

12-1

UPS System Technical Specifications

56

 

 

 

 

 

 

 

8-3

Standard Start-Up Procedure (Single UPS—SUS)

21

 

 

 

 

 

 

 

 

 

 

 

12-2

UPS System Floor Loading Table

56

 

 

 

 

 

 

 

8-4

Battery Start-Up Procedure (Single UPS—SUS)

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

Storage and Service

57

 

8-5

Manual Bypass Procedure (Single UPS—SUS)

22

 

 

 

8-6

Shutdown Procedure (Single UPS—SUS)

24

 

 

 

 

 

 

14

Warranty

58

 

 

 

 

 

 

 

8-7

Preliminary Checklist (Parallel UPS—MUS)

24

 

 

 

 

 

Español

59

 

 

 

 

 

 

 

8-8

Start-Up Procedure (Parallel UPS—MUS)

25

 

 

 

8-9

Shutdown Procedure (Parallel UPS—MUS)

26

 

 

Français

117

 

 

 

 

 

 

 

8-10

Switching to Manual Bypass Mode from Normal Mode

 

 

 

 

 

 

 

 

 

 

 

 

(Parallel UPS—MUS)

27

 

 

Русский

175

 

 

 

 

 

 

 

8-11

Switching to Normal Mode from Manual Bypass Mode

 

 

 

 

 

 

 

 

 

 

 

 

(Parallel UPS—MUS)

28

 

 

 

 

 

 

2

12-212-93-3141.indb 2

12/28/2012 11:16:51 AM

Page 2
Image 2
Tripp Lite SU120KX2 owner manual Table of Contents

SU120KX2 specifications

The Tripp Lite SU120KX2 is an advanced uninterruptible power supply (UPS) that provides reliable backup power and surge protection for critical devices. Engineered for small and medium-sized businesses, this UPS is ideal for safeguarding sensitive electronics such as servers, network devices, and telecommunications equipment.

One of the standout features of the SU120KX2 is its impressive 1200VA power capacity. This allows it to deliver significant run time during power outages, ensuring that your equipment remains operational until power is restored or until you can safely shut down your systems. With a pure sine wave output, this UPS simulates utility power, providing stable voltage and frequency to connected devices. This is particularly important for equipment that is sensitive to power fluctuations, as it helps to maintain optimal performance and longevity.

The SU120KX2 is equipped with multiple battery and surge protected outlets, providing flexibility for connecting various devices. It includes USB and serial connectivity options for easy communication with connected equipment, enabling monitoring of battery status and power conditions. An LCD screen provides real-time information on battery level, load capacity, and input/output voltage, ensuring users are informed about the status of their power supply.

Another notable feature is the built-in automatic voltage regulation (AVR). This technology helps to stabilize input voltage levels, correcting minor fluctuations without switching to the battery, thereby extending the life of the battery while ensuring your devices receive consistent and clean power. Furthermore, the SU120KX2 includes advanced battery management features that optimize battery performance and provide notifications for battery replacement when necessary.

For added convenience, the Tripp Lite SU120KX2 offers hot-swappable battery capabilities, allowing users to replace batteries without shutting down connected devices. This ensures that your critical operations are not interrupted, making it an ideal choice for businesses that cannot afford downtime.

Overall, the Tripp Lite SU120KX2 combines robust performance with reliable protection, making it a perfect solution for businesses looking to secure their electronic infrastructure against power disturbances. With its manageable size, advanced features, and user-friendly interface, the SU120KX2 stands out as a dependable UPS that meets the needs of various applications while ensuring the integrity and availability of your critical systems.