System Type

TGID Format

Motorola Type 2

N = Decimal Number

Decimal Format

Systems

H = Hexadecimal Number

NNNNN

 

i = I-Call ID

iNNNNN

 

 

Hexadecimal Format

 

 

HHHH

 

 

iHHHH

 

 

 

P25 Systems

N = Decimal Number

Decimal Format

 

H = Hexadecimal Number

NNNNN

 

i = I-Call ID

iNNNNNNNN

 

 

Hexadecimal Format

 

 

HHHH

 

 

iHHHHHH

 

 

 

EDACS Systems

A = Agency

AFS Format

 

F = Fleet

AA-FFS (Normal ID)

 

S = Sub-Fleet

AA-FF- (Partial Fleet ID)

 

N = Decimal Number

AA- (Partial Agency ID)

 

i = I-Call ID

Decimal Format

 

Only AFS Format is allowed for

NNNN

 

direct entry except for I-Call ID..

iNNNNN

 

 

 

LTR Systems

A = Area number

A-RR-UUU (Normal ID)

 

RR = Home Repeater Number

A-RR (Partial Repeater ID

 

U = Decimal Number

 

 

 

 

Note: A-RR (Partial Repeater ID) cannot be used with decimal formats.

Type II Special Status Bits

Type II Motorola Smartnet systems use these status bits for special transmissions such as emergency, patches, DES/DVP scrambled transmissions, and multiselects. Motorola trunking radios directly interpret them for their special functions, thus no difference is noticed by the person with the radio. The scanner however interprets these special talk group status bits as different talk groups entirely. Below is the conversion chart for these special status bits.

TT ID + # Usage

TT ID + # Usage

ID+0 Normal Talk group

ID+8 DES/DVP Encryption talk group

 

 

ID+1 All Talk group

ID+9 DES All Talk group

 

 

ID+2 Emergency

ID+10 DES Emergency

 

 

ID+3 Talk group patch to another

ID+11 DES Talk group patch

 

 

ID+4 Emergency Patch

ID+12 DES Emergency Patch

 

 

ID+5 Emergency multi-group

ID+13 DES Emergency multi-group

 

 

ID+6 unassigned

ID+14 unassigned

 

 

ID+7 Multi-select (initiated by dispatcher)

ID+15 Multi-select DES TG

 

 

Therefore, if a user was transmitting a multi-select call on talk group 1808, the scanner would actually receive those transmissions on 1815.

Some common uses of these status bits are as follows:

When a user hits their emergency button, all conversations on the talk group revert to the emergency status talk group (ID+2) until the dispatch clears the emergency status.