1. General Information
The Riva Heat Only is a high efficiency,
Key Features:
•Wall mountable - saving valuable floor space.
•Several flue options available
•Electronic spark ignition
•Safety flow switch - positioned on the main circuit, which monitors the flow and protects the main heat exchanger from thermal shock should there be a lack of water in the system.
•Frost protection - contains an integral frost protection system to prevent frost damage which can occur in areas susceptible to very cold weather conditions.
•Boiler operation recognition system - should the boiler not be used for longer than 24 hours, it then performs a controlled system test to ensuring the motorized components within the boiler do not become inoperable due to lack of use.
•Gas valve modulation - the gas input modulates based off central heating temperature to within ± 2 ºF
•Diagnostic information system equipped with three LED diagnostic lights for quick error assessment.
2. Technical Information (M130.30CR)
GENERAL
Height | in | 27.7 |
Width | in | 15.7 |
Depth | in | 12.8 |
Weight | lb | 79.4 |
CENTRAL HEATING
Maximum working temp. |
| °F | 185 |
Temp. Regulation range* |
| °F | |
Maximum pressure |
| psi | 30.0 |
Minimum pressure |
| psi | 4.35 |
Max head loss (at 4.4 GPM) |
| ft | 10 |
*At the minimum useful output |
|
| |
|
|
|
|
RIVA HEAT ONLY MANUAL - REV A | 9 |