VIVOTEK

Applications > DI and DO

Advanced Mode

Digital input: Select High or Low to define normal status for the digital input. The Network Camera will report the current status.

Digital output: Select Grounded or Open to define normal status for the digital output. The Network Camera will show whether the trigger is activated or not.

Applications > Tampering detection

This section explains how to set up camera tamper detection. With tamper detection, the camera is capable of detecting incidents such as redirection, blocking or defocusing, or even

spray paint.

Please follow the steps below to set up the camera tamper detection function:

1.Check Enable camera tampering detection.

2.Enter the tamper trigger duration. (10 sec. ~ 10 min.) The tamper alarm will be triggered only when the tampering factor (the difference between current frame and pre-saved background) exceeds the trigger threshold.

3.Set up the event source as Camera Tampering Detection on Event > Event settings > Trigger. Please refer to page 108 for detailed information.

106 - User's Manual