ÎPress the pedal for changing the brushes downward beyond its resistance.
ÎDrive the appliance in reverse till the disk brush is free.
ÎRemove the disk brush and place the new disk brush in front of the appliance.
ÎDrive the appliance forward over the disk brush.
ÎPress the pedal for driving out the run- ning gear and lock it to the left. The brush will lock into the brush drive.
ÎSet the advance speed.
Replace pump hose
ÎEmpty the dirty and fresh water tank.
ÎRemove the detergent bottle from the detergent holder.
ÎLoosen the tank fastening screw and tilt the tank upward.
The metering pump is located behind the batteries.
1Covering lid
2Cover
3Hose switch
4Pump hose
5Rotor
ÎRemove covering lid.
ÎRemove cover.
18English
ÎRemove the hose holder with the pump hose (turn manually to remove the rotor manually).
ÎReplace pump hose.
ÎMetering pump and appliance are brou- ght into operational state by performing the same steps in the reverse direction.
Maintenance contract
To ensure a reliable operation of the ap- pliance maintenance contracts can be con- cluded with the competent Windsor sales office.
Frost protection
In case of danger of frost:
ÎEmpty the fresh and dirty water reser- voirs.
ÎStore the appliance in a
Troubleshooting
Danger
Risk of injury. Turn the program selection switch to "OFF" and disconnect the mains plug before performing any works on the ap- pliance. Also turn the key switch to "0" and press the emergency stop switch.
ÎDrain and dispose of the dirty water and the residual fresh water.
In case of faults that cannot be remedied using the table below please contact the cu- stomer service.
Note
If the display shows interruptions, first set the program selection switch to OFF or dri- ving and switch off the key switch (if availa- ble). Wait for 15 seconds. Turn on the appliance again. If the display still shows a fault, then rectify the fault according to the following table or call Customer Service.