Windsor 22 SP manual Faults, Error, Remedy

Models: 22 22 SP

1 72
Download 72 pages 54.68 Kb
Page 20
Image 20
Faults

Faults

Error

Remedy

Appliance cannot be started

Check batteries, charge if required. Fully charge battery

 

if it has got discharges so that the electronics system can

 

release the function lock.

 

Check battery pole fuse at the positive pole of the battery

 

(100 A); inform customer service if the fuse is defective.

Insufficient water quantity

Check fresh water level, refill tank if necessary.

 

Check hoses for blockages; clean if required.

 

Saber Compact 22 SP: Remove the cover of the water

 

supply at the suction head and clean the water canal.

 

 

Insufficient vacuum perfor-

Clean the seals between dirty water reservoir and cover

mance

and check for tightness, replace if required.

 

 

 

Clean the lint filter.

 

Clean the squeegee blades on the squeegee tool, turn or

 

replace if required

 

Check if the vacuum hose and squeegee tool are chok-

 

ked, clean if required

 

Check the vacuum hose for tightness; replace if required.

 

Check if the cover on the dirty water discharge hose is

 

closed

 

 

 

Check the setting of the squeegee tool.

 

Check whether the turbine is running and is creating un-

 

der-pressure; call Customer Service, if required.

 

 

Insufficient cleaning result

Drive in the running gear.

 

Check the brushes for wear, replace if required.

 

Check detergent metering (optional).

Detergent dose gets reduced

Replace pump hose of the metering pump.

The detergent bottle gets de-

Tilt out the detergent intake and take out the detergent

formed when detergent is suk-

bottle.

ked out of it. There is no air

Close the lid of the detergent bottle.

coming in to equalise the

Pull out the valve (rubber cap) and clean it in warm water.

pressure.

Replace the valve.

Brushes do not turn

Check if foreign matters block the brushes; remove for-

 

eign matter if required.

Drain hose for dirtyy water is

Open metering equipment at the drain hose. Pull out the

blocked

vacuum hose from suction beam and close it by hand.

 

Set the program selection switch to suction or vacu-

 

uming. The blockage will be sucked out from the drain

 

hose into the dirty water tank.

20English

Page 20
Image 20
Windsor 22 SP manual Faults, Error, Remedy