Wolf ICBCT30I ˜ L1 N, 3 8 1 m m I N D U C T I O N C O O K TO P S, Required power supply, 3NL1˜

Models: ICBCT30I

1 88
Download 88 pages 22.45 Kb
Page 16
Image 16
3 8 1 m m I N D U C T I O N C O O K TO P S

I M P O RTA N T N OT E

Be aware of local codes and ordi- nances when installing your service.

W O L F INDUCTION  COOKTOPS

ELECTRICAL   R E Q U I R E M E N T S

Verify that power is disconnected from the electrical box before proceeding.

3 8 1 m m I N D U C T I O N C O O K TO P S

Required power supply:

Single phase: 220-240V AC; 50 Hz

3phase: 380-410V AC; 50 Hz

Maximum connected load:

Single phase: 3.6 kW

3phase: 3.6 kW

Total amps:

Single phase: 16 amps

3phase: 16 amps

7 6 2 m m I N D U C T I O N C O O K TO P S

Required power supply:

Single phase: 220-240V AC; 50 Hz

3phase: 380-410V AC; 50 Hz

Maximum connected load:

Single phase: 7.2 kW

3phase: 3.6 kW

Total amps:

Single phase: 32 amps

3phase: 16 amps

9 1 4 m m I N D U C T I O N C O O K TO P S

Required power supply:

Single phase: 220-240V AC; 50 Hz

3phase: 380-410V AC; 50 Hz

Maximum connected load:

Single phase: 11.2 kW

3phase: 4 kW

Total amps:

Single phase: 49 amps

3phase: 18 amps

Refer to the wiring diagram showing the connections for each lead to the terminal box on the unit.

˜ L1 Required power supply:Maximum connected load:Total amps:7 6 2 m m I N D U C T I O N C O O K TO P S9 1 4 m m I N D U C T I O N C O O K TO P S˜ L1 3NL1˜Manual backgroundManual backgroundManual backgroundManual background

N Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

3NL1˜

L2

L3

N

Single phase wiring diagram

3phase wiring diagram

16

Page 16
Image 16
Wolf ICBCT30I ˜ L1 N, 3 8 1 m m I N D U C T I O N C O O K TO P S, Required power supply, Maximum connected load, 3NL1˜