INSTALLATION I N S T R U C T I O N S

INSTALLATION I N S T R U C T I O N S

INSTALLATION S P E C I F I C AT I O N S

The illustrations on pages 8–13 provide the overall dimensions, installation specifications and countertop cut-out for each of the Wolf induction cooktop models.

These cooktops are designed to fit a standard 610 mm deep base cabinet with a 635 mm deep countertop. Before making the counter- top cut-out, verify that the cooktop will clear the side walls of the base cabinet below.

Clearance is required for the terminal block located at the right rear of the cooktop. Refer to the illustration below for dimensions.

F R A M E D I N D U C T I O N C O O K TO P S

IMPORTANT NOTE: A minimum height clear- ance of 152 mm is required between the coun- tertop and any combustible surface directly below the cooktop. This includes upper edges of drawers located directly below unit. If a shelf is installed below the unit, a 25 mm gap at the rear of the cabinet shelf is necessary to allow for proper ventilation. Failure to do so could result in decreased performance or product damage.

Wolf induction cooktops are designed to be installed in combination with other cooktop units.

IMPORTANT NOTE: When multiple cooktops and/or modules are installed side by side, refer to countertop cut-out dimensions on page 11.

Wolf induction cooktops can accommodate a Wolf downdraft ventilation system. Refer to installation instructions provided with the downdraft for additional specifications.

U N F R A M E D I N D U C T I O N C O O K TO P S

IMPORTANT NOTE: A minimum height clear- ance of 165 mm is required between the coun- tertop and any combustible surface directly below the cooktop. This includes upper edges of drawers located directly below unit. If a shelf is installed below the unit, a 25 mm gap at the rear of the cabinet shelf is necessary to allow for proper ventilation. Failure to do so could result in decreased performance or product damage.

IMPORTANT NOTE: Unframed induction cooktops are not designed to be installed in combination with other cooktops.

IMPORTANT NOTE: Unframed induction cooktops cannot be installed with a downdraft ventilation system.

For installation options of the unframed induc- tion cooktops, refer to Unframed Installation on pages 14–15.

32 mm

 

 

56

 

mm

 

22 mm

 

84

24

mm

 

mm

 

Terminal block dimensions

7

Page 7