Wolf ICBCT30I For Single Phase Install Line, Neutral, For 3phase Install L1, L2, L3, Neutral

Models: ICBCT30I

1 88
Download 88 pages 22.45 Kb
Page 17
Image 17
For Single Phase Install (Line, Neutral,

INSTALLATION I N S T R U C T I O N S

ELECTRICAL   R E Q U I R E M E N T S

The complete appliance must be properly grounded at all times when electrical power is applied.

NOTE: Improper connection can result in a fire hazard.

Before obtaining access to terminals, all supply circuits must be disconnected.

Open the terminal box to expose the screws with corresponding numbers. Run the cord through the strain relief hole and into the terminal box.

For Single Phase Install (Line, Neutral,

Ground): Loosen the 1, 5, and ground screws. Attach the Neutral wire to the number 5 position. Line should be attached to the 1 postion and attach the ground to the corre- sponding ground screw.

For 3phase Install (L1, L2, L3, Neutral,

Ground): Loosen the 1, 2, 3 and remove the copper bars. Loosen 5 and ground screws. Attach L1 to position 1. L2 to position 2. L3 to position 3. Neutral wire to position 5 and attach the ground to the corresponding ground screw.

After tightening the screws, tighten down the cord strain relief and close the cover to the terminal box without pinching any of the wires.

IMPORTANT NOTE: Connection of this appli- ance should be through a fused connection unit or a suitable isolator, which complies with national and local safety regulations. The on/off switch should be easily accessible after the appliance has been installed. If the switch is not accessible after installation (depending on country) an additional means of disconnec- tion must be provided for all poles of the power supply. When switched off there must be an all pole contact gap of 3 mm in the isolator switch. This 3 mm contact disconnect gap must apply to any isolator switch, fuses and/or relays according to EN60335.

Copper bars must be removed from posi- tions 1, 2, and 3 when connecting to 3phase power.

17

Page 17
Image 17
Wolf ICBCT30I installation instructions For Single Phase Install Line, Neutral, For 3phase Install L1, L2, L3, Neutral