The illustrations below provide installation specifications for Model ICBCT30I/S.

For ease of installation, 838 mm cabinets are recommended for installation of Model ICBCT30I/S.

A Wolf 762 mm or 914 mm built-in single oven may be installed below Model ICBCT30I/S. For this installation, unless you are using cabinets deeper than 610 mm, it is recommended that the electrical supply be placed in the base cabinet to the right of the oven.

Refer to installation instructions provided with the built-in oven for additional specifications.

If Model ICBCT30I/S is installed above cabinets, the electrical placement is not critical. The appliance shall be installed in such a way to allow disconnection of the appliance from the supply mains after installation.

I N S TA L L AT I O N S P E C I F I C AT I O N S – M O D E L I C B C T 3 0 I / S

 

533 mm

 

 

 

 

 

 

OVERALL

 

 

 

 

 

 

DEPTH

 

 

 

 

 

 

 

SIDE

 

 

 

 

762 mm

 

CABINET

 

 

 

 

 

 

 

762 mm min

 

 

OVERALL WIDTH

 

330 mm

 

 

 

 

 

COUNTERTOP

 

 

 

 

max

TO COMBUSTIBLE

 

 

 

 

 

457 mm min

 

 

 

 

MATERIALS

64 mm

96 mm

51

51 mm TO

SEE COUNTERTOP

51 mm TO

 

 

COMBUSTIBLE*

CUT-OUT BELOW

COMBUSTIBLE*

TERMINAL BOX

 

mm*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

114 mm

Overall Dimensions

 

 

 

89 mm

E

 

 

 

914 mm

 

254 mm

 

 

 

 

 

 

 

 

 

FLOOR TO

 

 

 

 

 

 

COUNTERTOP

 

 

 

M O D E L I C B C T 3 0 I / S

 

 

 

762 mm OVEN OPENING

 

 

 

 

 

 

 

Overall Width

762 mm

 

 

 

 

 

Overall Height

64 mm

 

 

 

 

 

Overall Depth

533 mm

 

 

 

 

 

Minimum Cabinet Depth

578 mm

*Minimum clearance from cooktop cut-out to combustible materials up to 457 mm above countertop.

 

 

NOTE: Electrical location applies only to installation with built-in oven.

 

 

 

 

 

 

 

 

Minimum Height Clearance*

96 mm

 

 

721 mm

 

 

 

 

 

 

 

 

Cut-Out Width

721 mm

 

 

CUT-OUT WIDTH

 

 

 

 

 

 

Cut-Out Depth

489 mm

 

 

 

 

 

*Minimum 152 mm clearance is required

 

 

489 mm

 

between countertop and any combustible

 

 

 

 

 

CUT-OUT

 

surface directly below the cooktop.

 

 

DEPTH

 

 

 

 

 

 

For detailed terminal block dimensions,

 

 

 

 

 

 

 

 

 

 

refer to the illustration on page 7.

 

FRONT

 

64 mm min

 

Dimensions may vary to ± 3 mm.