Xantrex Technology RS232-XPD Installation and Configuration, Initial Inspection, Jumper Selection

Models: RS232-XPD

1 60
Download 60 pages 29.02 Kb
Page 20
Image 20
JUMPER SELECTION

Installation and Configuration

Initial Inspection

 

JUMPER SELECTION

J2

Local OVP control selection

[closed] [default]. See page 28.

 

 

[open] Front Panel OVP Control.

J3

User TTL shutdown (S/D)

[1-2] User TTL S/D line active low. See page 31.

 

selection

[2-3] [default] User TTL S/D line active high.

J20

Remote OVP Control Selection

[closed] [default]. See page 28.

 

 

[open]

J10

RS-232 (J4) transmit and

[3-1]

Receive on pin 3 [default]

 

receive pin selection

[4-6]

Transmit on pin 2 [default]

 

 

[3-5]

Receive on pin 2

 

 

[4-2]

Transmit on pin 3

J16 RS-232 flow control selection of RTS/CTS (ready to send/clear to send) or DTR/DSR (data terminal ready/data set ready)

J17 RS-232 flow control selection of RTS/CTS or DTR/DSR

[1-3][4-6] [default] RTS input on pin 7 (used with CTS output on pin 8)

[3-5][4-6] DTR input on pin 4 (used with DSR output on pin 6)

[2-4][[3-5] [default] CTS output on pin 8 (used with RTS input on pin 7)

[2-4][1-3] DSR output on pin 6 (used with DTR input on pin 4)

Note: All other jumpers are not user-selectable.

 

 

LED INDICATORS

D1

Red Diagnostic LED

Bus error or soft restart on Slave circuitry.

D4

Red Diagnostic LED

Soft restart on Master circuitry.

D5

Green Diagnostic LED

Bus error on Master circuitry.

 

 

EPROMS

U18

Slave EPROM

See revision number stamped on EPROM.

U1

Master EPROM

See revision number stamped on EPROM.

Figure 2.3 RS-232 Interface PCB

18

Operating Manual for RS-232 for XPD Series Power Supply

Page 20
Image 20
Xantrex Technology RS232-XPD Installation and Configuration, Initial Inspection, Jumper Selection, Led Indicators, Eproms