Operation

Accumulated Status, Status, and Fault Registers

Table 3.8 Accumulated Status, Status, and Fault Registers

Condition

Mnemonic

Bit Position

Bit Weight

Constant voltage operation

CV

0

1

 

 

 

 

Constant current operation

CC

1

2

 

 

 

 

Not used

2

4

 

 

 

 

Overvoltage protection tripped

OV

3

8

 

 

 

 

Over temperature protection tripped

OT

4

16

 

 

 

 

Supply external shutdown active (J21-1)

SD

5

32

 

 

 

 

Foldback mode operation

FOLD

6

64

 

 

 

 

Remote programming error

ERR

7

128

 

 

 

 

Power ON (accumulated status, status

PON

8

256

registers only)

 

 

 

Remote mode (accumulated status, status

REM

9

512

registers only)

 

 

 

AC fail condition

ACF

10

1024

 

 

 

 

Output fail condition

OPF

11

2048

 

 

 

 

Sense protection tripped

SNSP

12

4096

Notes:

1.All mnemonics can be masked or unmasked.

2.The error (ERR) bit is reset in the accumulated status, status, and serial poll registers with an error query (ERR?).

3.The accumulated status register is cleared with an accumulated status query (ASTS?).

4.A fault is cleared with a fault query (FAULT?).