Installation and Configuration
Communications
Once flow control is selected as option, two flow control methods are available. You can use the rear panel XON switch to select either
Table 2.4 Hardware/Software Flow Control Selection
XON Switch Setting | Condition |
1 | Hardware Flow Control |
| (CTS/RTS or DTR/DSR protocol) |
0 | Software Flow Control |
| (XON/XOFF protocol) |
Software This software protocol uses special characters that synchronize device
Flow Control communications. The device sends the control code XOFF (ASCII value 13 hex) when it is not ready to receive data. The device sends the control code XON (ASCII value 11) when it is ready to resume receiving data.
To choose XON/XOFF protocol, select the XON switch position shown in
Table 2.4.
Hardware Hardware flow control protocol requires a dedicated control line on the
when it is ready to receive data. You can designate either RTS/CTS or DTR/DSR protocol for the
Set the XON switch for hardware control using the information in Table 2.4. With hardware flow control selected,
Note:When resetting the flow control switches during a working session, turn the power supply OFF and then ON again to ensure that the new settings are put into effect.
Table 2.5 Jumper/Pin Settings for RTS/CTS Flow Control (Default)
| Jumper Connections |
|
RTS (Input to | J17 to | 7 |
|
|
|
CTS (Output to | J16 to | 8 |
Release 1.2 | 21 |