TC2 204060 Series BattChg Owners Guide.book Page 15 Friday, July 8, 2011 11:44 AM

 

 

Preparing For Installation

Note that every jurisdiction will have different requirements as will each

Battery Bank Size Requirements

application, so research the regulations for your local jurisdiction to

 

 

 

 

determine which wire size and type is correct based on the maximum AC

The Truecharge2 Battery Charger is designed to work with a minimum

input current marked on the chargers and given in “AC Input

battery bank size. Each bank should meet the minimum Ah rating shown in

Specifications” on page 54.

Table 4. These minimum values are based on twice the charger’s rated

Other examples of AC wiring requirements:

maximum charging current. For example, a 20-amp charger will charge a

minimum 40 Ah battery. If you are considering new batteries, please

• For marine applications, the American Boat & Yacht Council (ABYC)

consult the battery’s manufacturer for their recommendation based on the

maximum charging current of your charger.

requires stranded wire, which is more robust than solid wire when

 

 

 

 

exposed to vibration.

 

 

 

 

IMPORTANT: If the battery manufacturer has specified the maximum

• For RV applications, the United States National Electrical Code (NEC)

charge current, please follow their recommendation.

allows solid wire in multi-conductor cable, however, stranded wire is

 

 

 

 

also acceptable which will withstand vibration better.

Table 4 Minimum Battery Bank Size

The AC wiring supplying the Truecharge2 Battery Charger must be

 

 

 

 

12 Vdc Models

Minimum Battery Bank Size (Ah)

 

 

protected by the correct size and type of branch-circuit rated fuse or breaker

 

 

 

 

 

to meet the applicable installation codes. If a fuse is used instead of a

TC2012

40

 

 

breaker, a correctly rated disconnect switch is required ahead of the fuse so

TC4012

80

 

 

that power can be turned off, allowing fuse replacement and safe

 

 

 

 

TC6012

120

 

 

maintenance of other equipment on the mains circuit.

 

 

 

24 Vdc Models

Minimum Battery Bank Size (Ah)

 

 

 

 

 

 

 

TC1024

20

 

 

 

TC2024

40

 

 

 

TC3024

60

 

 

 

 

 

 

 

 

 

975-0526-01-02

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 27
Image 27