TC2 204060 Series BattChg Owners Guide.book Page 53 Friday, July 8, 2011 11:44 AM

Symptom

The Truecharge2 Battery Charger will not perform equalization.

Possible Cause

Solution

 

 

Battery is the wrong type, or set

Determine if the battery type is set to

to the wrong type to equalize.

GEL or AGM. These battery types

 

cannot be equalized.

Not all batteries are fully

The charger will wait for all batteries to

charged.

be in float stage of three-stage charging

 

or rest stage of two-stage charging

 

before attempting to equalize (the ready

 

indicator LED will illuminate).

An active fault is present on the

Clear the active fault by disconnecting

bank you are attempting to

the AC power source and finding the

equalize.

cause of the fault from “Interpreting

 

Fault and Warning Indicators” on page

 

43.

 

 

975-0526-01-02

Troubleshooting

53

Page 65
Image 65