TC2 204060 Series BattChg Owners Guide.book Page 57 Friday, July 8, 2011 11:44 AM

Specifications

Protection Features

Protection Features

Battery reverse polarity

Protected by replaceable DC output

 

fuses

 

 

Over-voltage limits

The Truecharge2 Battery Charger will

 

stop charging if the output voltage is

 

above

 

16.6 ±0.5 Vdc for 12 Vdc units,

Battery under-temperature protection

Charger shuts down if battery temperature below –25 °C (–13 °F) is sensed by the battery temperature sensor (BTS).

 

33.2 ±0.1 Vdc for 24 Vdc units.

 

 

Output current limit

 

TC2012:

20 +10% A

TC4012:

40 +10% A

TC6012:

60 +10% A

TC1024:

10 +10% A

TC2024:

20 +10% A

TC3024:

30 +10% A

 

 

Over-temperature

Shutdown at 65 ±5 °C (149 ±9 °F)

(measured internally)

 

 

Restart at 60 ±5 °C (140 ±9 °F)

 

 

Battery over-temperature

Charger shuts down if battery

protection

temperature above 70 °C (158 °F) is

 

sensed by the battery temperature

 

sensor (BTS).

Regulatory Approvals

Safety

North America NRTL approved to CSA E60335-2-29, UL1236 including the marine supplement, and UL1564.

ABYC E11 - Alternating Current and Direct Current Electrical Systems on Boats, and

ABYC A31 - Battery Chargers and Inverters. European Union CE marked for the Low Voltage Directive 2006-95-EC,

(complying with EN60335-2-29 Battery Chargers). EN 28846 - Small Craft Electrical Devices, Protection against ignition of surrounding flammable gases.

Australia Designed to IEC60335-2-29 including Australian deviations.

EMC

North America Class B according to FCC Part 15B and Industry Canada ICES-003.

European CE marked for the EMC Directive 2004-108-EC (complying with EN55014-1, EN55014-2, EN61000-3-2, and EN61000-3-3).

 

 

975-0526-01-02

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 69
Image 69
Xantrex Technology TC2 204060 manual Protection Features, Regulatory Approvals