Configuring the Truecharge2 Battery Charger
Once the charger is connected to at least one battery bank and to AC, it is live and it may be configured. The indicator LEDs on the onboard display will illuminate for a second (power on test) before reporting charging and battery status information.
Configuring the Charger Mode
NOTE: By default, the Charger Mode is set to
1. Press and hold the Charger Mode Select button for three seconds to advance to the next setting.
2. Select the proper charger mode.
The LEDs will indicate which of the two modes is being selected:
Configuring the Battery Bank Type
Figure 11 Onboard Display Panel
NOTE: By default, the battery type is set to Flooded.
1.Press and hold the Battery Type Select button for three seconds to advance to the next setting.
2.Select the proper battery type.
The LEDs will indicate which of the five types is being selected: Flooded (default), GEL, Lead Calc., AGM, and Custom. The Custom setting is indicated when all four battery type LEDs are illuminated. This setting should only be used if a custom algorithm has been programmed by Xantrex or a designated OEM.
|