To facilitate the use of ChipScope to analyze OPB IIC hardware, the iic.cdc file is included in the ml403_ppc_opb_iic/chipscope directory. The iic.cdc is used to insert a ChipScope ILA core into the opb_iic core. The following steps are used to insert a core and analyze OPB IIC problems with ChipScope.

1.Invoke XPS. Run Hardware Generate Netlist.

2.In the iic.cdc file, change the path <design_directory> name to the directory in which the design files are installed. Three paths need to be changed.

3.Run Start Programs ChipScope Pro ChipScope Inserter

4.From ChipScope Inserter, run File Open Project ii.cdc. Figure 22 shows the ChipScope Inserter setup GUI.

X979_22_012907

Figure 22: ChipScope Inserter Setup