Using ChipScope with OPB IIC
XAPP979 (v1.0) February 26, 2007 www.xilinx.com 18
R
Using
ChipScope with
OPB IIC
Tofacilitate the use of ChipScope to analyze OPB IIC hardware, the iic.cdc file is included in
the ml403_ppc_opb_iic/chipscope directory. The iic.cdc is used to insert a
ChipScope ILA core into the opb_iic core. The following steps are used to insert a core and
analyze OPB IIC problems with ChipScope.
1. Invoke XPS.Run Hardware Generate Netlist.
2. In the iic.cdc file, change the path <design_directory> name to the directory in which
the design files are installed. Three paths need to be changed.
3. Run Start Programs ChipScope Pro ChipScope Inserter
4. From ChipScope Inserter,r un File Open Projectii.cdc.Figure 22 shows the ChipScope
Inserter setup GUI.
Figure 22: ChipScope Inserter Setup
X979_22_012907