When communicating via the parallel port | Printer | Computer | |
(refer to Figure 12), the previously | |||
|
| ||
mentioned parameters are not considered. |
|
| |
Refer to page 46 to configure the |
|
| |
communication parameters for the printer. |
| ||
The values selected must be the same as |
| ||
male | PC | ||
those used by the host equipment connected |
| ||
| female | ||
to the printer. |
| ||
|
| ||
For serial and parallel pinout and technical |
|
| |
information, refer to the Appendix on |
|
| |
page 85. |
| ||
|
| male |
Cabling Requirements |
| |
Data cables must be fully shielded and fitted | 10’ (3 m) maximum | |
with metal or metalized connector shells. |
| |
Figure 12 | ||
Shielded cables and connectors are required | ||
to prevent radiation and reception of |
| |
electrical noise. |
| |
To minimize electrical noise pickup in the cable: |
|
�Keep data cables as short as possible.
�Do not bundle the data cables tightly with the power cords.
�Do not tie the data cables to power wire conduits.
NOTE: Zebra printers comply with FCC “Rules and Regulations,” Part 15, for Class B Equipment, using fully shielded data cables. Use of unshielded cables may increase radiated emission above the Class B limits.
NOTE:
PAGE 12 OF 57 | 0808 |