Chapter 2 Hardware Installation and Connections

Refer to Chapter 5 on page 75 for the gauge of wire to use for the frame ground connections.

Refer to Chapter 5 on page 75 for the IES-6000M’s dimensions, weights and power consumption.

Failure to use the proper screws may damage the unit.

2.2.2 Mounting the Main Chassis on a Rack

Make sure that nothing obstructs the airflow of the main chassis.

If you are facing the IES-5106M or IES-5112M front panel, the fan exhaust vents are located on the right side panel of the unit and the fans along with the intake vents are located on the left side panel.

Figure 6 IES-5106M Airflow

Figure 7 IES-5112M Airflow

If you are facing the IES-6000M front panel, the fan intake vents are located on the bottom of the front and side panels of the unit. The fan exhaust vents are located on the top of the front and side panels, right above the fan module.