Chapter 2 Hardware Installation and Connections
2.6.3 Telco-50 Cables
Telco-50 cables are used for data and voice applications with MDFs (Main Distribution Frame), patch panels and distribution boxes. They can also be used as extension cables. Telco-50 cables are made up of 25 twisted-pair copper wires.
Connect a Telco-50 connector to one end of the cable (see the User’s Guide for the individual line card for pin assignments) and connect the other end directly to an MDF. Alternatively, attach RJ-11 connectors and connect directly to DSL modems or telephones.
Note: The cable shown below uses a 90-degree Telco-50 connector, where the cable extends from the side of the connector (at ninety degrees to the port). For rear- panel splitter chassis connections using the VOP-1248G VoIP line card, use a 180-degree Telco-50 connector (where the cable extends from the base of the connector directly opposite the port).
Figure 38 Telco-50 Cable with RJ-11 Connectors
2.6.4 MDF Connection Scenarios
The following figure gives an overview of possible scenarios for the IES using the line cards and splitter cards. Data and voice signals can coexist on the same telephone wiring.
48 | |
IES-5106M / IES-5112M / IES-6000M User’s Guide | |
| | |