Chapter 38 Access Control

38.3.2 Supported MIBs

MIBs let administrators collect statistics and monitor status and performance.

The Switch supports the following MIBs:

SNMP MIB II (RFC 1213)

RFC 1157 SNMP v1

RFC 1493 Bridge MIBs

RFC 1643 Ethernet MIBs

RFC 1155 SMI

RFC 2674 SNMPv2, SNMPv2c

RFC 1757 RMON

SNMPv2, SNMPv2c or later version, compliant with RFC 2011 SNMPv2 MIB for IP, RFC 2012 SNMPv2 MIB for TCP, RFC 2013 SNMPv2 MIB for UDP

38.3.3SNMP Traps

The Switch sends traps to an SNMP manager when an event occurs. The following tables outline the SNMP traps by category.

An OID (Object ID) that begins with “1.3.6.1.4.1.890.1.5.8” is defined in private MIBs. Otherwise, it is a standard MIB OID.

The OIDs beginning with “1.3.6.1.4.1.890.1.5.8.68” are specific to the MES3500-24 switch.

The OIDs beginning with “1.3.6.1.4.1.890.1.5.8.57” are specific to the MES3500-24F switch.

Table 120 SNMP System Traps

OPTIONOBJECT LABELOBJECT ID

DESCRIPTION

coldstart

coldStart

1.3.6.1.6.3.1.1.5.1

This trap is sent when the Switch is turned

 

 

 

on.

 

 

 

 

warmstart

warmStart

1.3.6.1.6.3.1.1.5.2

This trap is sent when the Switch restarts.

 

 

 

 

temperature

TemperatureEventOn

1.3.6.1.4.1.890.1.5.8.68.27.2.1

This trap is sent when the temperature goes

 

 

1.3.6.1.4.1.890.1.5.8.57.27.2.1

above or below the normal operating range.

 

 

 

 

 

 

 

 

TemperatureEventClear

1.3.6.1.4.1.890.1.5.8.68.27.2.2

This trap is sent when the temperature

 

 

1.3.6.1.4.1.890.1.5.8.57.27.2.2

returns to the normal operating range.

 

 

 

 

 

 

 

voltage

VoltageEventOn

1.3.6.1.4.1.890.1.5.8.68.27.2.1

This trap is sent when the voltage goes

 

 

1.3.6.1.4.1.890.1.5.8.57.27.2.1

above or below the normal operating range.

 

 

 

 

 

 

 

 

VoltageEventClear

1.3.6.1.4.1.890.1.5.8.68.27.2.2

This trap is sent when the voltage returns to

 

 

1.3.6.1.4.1.890.1.5.8.57.27.2.2

the normal operating range.

 

 

 

 

 

 

 

292

 