Chapter 45 Troubleshooting

I cannot see some of Advanced Application submenus at the bottom of the navigation panel.

The recommended screen resolution is 1024 by 768 pixels. Adjust the value in your computer and then you should see the rest of Advanced Application submenus at the bottom of the navigation panel.

There is unauthorized access to my Switch via telnet, HTTP and SSH.

Click the Display button in the System Log field in the Management > Diagnostic screen to check for unauthorized access to your Switch. To avoid unauthorized access, configure the secured client setting in the Management > Access Control > Remote Management screen for telnet, HTTP and SSH (see Section 38.11 on page 310). Computers not belonging to the secured client set cannot get permission to access the Switch.

45.3 Switch Configuration

I lost my configuration settings after I restart the Switch.Make sure you save your configuration into the Switch’s

nonvolatile memory each time you make changes. Click Save at the top right corner of the web configurator to save the

configuration permanently. See also Section 37.3 on page 284 for more information about how to save your configuration.

332

 

MES3500-24/24F User’s Guide